10.0 finish framing - after appliance installation
10.1 framing with non-combustibles
single-sided flush
Ceiling
minimum framing
Ref
TLV50L
K
E
65 13/16" (1672mm)
F
J
Optional - Appliance does not need to be elevated above floor
73" (1854mm)
L
note:
The TLV series requires a minimum enclosure/ceiling height, as illustrated (dimension L), measured from the bottom
of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations
that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent
pipes and combustibles.
finish framing - after appliance installation
L
J
E
TLV62L
TLV74L
48 3/16" (1224mm)
20 1/8" (511mm)
77 13/16" (1976mm)
89 13/16" (2281mm)
91" (2311mm)
note:
Shaded components (finish framing) must be
non-combustible materials.
Finish framing must be built after the appliance has
been placed in its final position and venting
connected.
K
F
Drywall
Insulation
W415-4127 / B-0 / 03.25.24
EN