Noise Level
Supplying Power
Direction of the Cut-off Wheel
4
Unitom-50
Instruction Manual
Approx. 73 dB (A) measured at idle running, at a distance of
1.0 m/39.4" from the machine.
Check that the mains voltage corresponds to the voltage
stated on the type plate on the side of the machine.
Unitom-50 is factory mounted with an electric cable. Mount a
plug on the cable according to the following:
50 hz
Phase
Black and brown
Earth Yellow/green
Check that the cut-off wheel rotates in the direction indicated on
the label attached to the guard of Unitom-50. If the direction of
rotation is incorrect:
50 hz
Switch two of the phases
IMPORTANT
L
Black
1
L
Red
2
L
Orange
3
Earth Green
Switch phases L
60 hz
60 hz
and L
1
2