18.2.6 Air intake duct cleaning
Periodically check that the air intake duct is
free from obstructions (dust, animal hair ...) and
remove them if necessary.
18.3 EXTRAORDINARY MAINTENANCE
Maintenance operations must be carried out
with the stove cold and with the power supply
disconnected.
Extraordinary maintenance activities must
be carried out by staff from the Authorised
Assistance Centre.
Do not wait for components to be deteriorated by
use before proceeding with their replacement.
Replace a worn component before it is completely
broken to prevent any damage caused by sudden
component breakage.
PARTS / FREQUENCY
Deep combustion chamber
and fire pot cleaning
Door gasket
Chimney
Smoke duct
Schedule the above extraordinary maintenance
activities with the Authorised Assistance Centre.
18.3.1 Deep combustion chamber
cleaning
This operation must be carried out by a Ravelli
Assistance Centre.
Schedule this type of cleaning with the Ravelli
Assistance Centre.
To clean the combustion chamber, proceed as
described below.
STEP
ACTION
1
Remove the pellet chute
2
Remove the ash grid
3
Remove the fire pot
4
Remove flame trap
5
Remove side vermiculite
6
Remove central vermiculite
1 SEASON
X
X
X
X
Fig. 18.5
ENGLISH
Fig. 18.6
Fig. 18.7
Fig. 18.8
Fig. 18.9
183