This type of installation (Fig. 6.6) requires a
horizontal section to connect to a pre-existing
chimney pot.
Respect the slope indicated in figure, in order
to reduce the ashes depositing in the horizontal
tube. In the lower part of the chimney pot, there
is a "T" type fitting installed with inspection cap,
in the same was as the chimney pot opening.
It is prohibited to install a 90° bend for the initial
segment, since the ashes would quickly obstruct
smoke passage, causing draught problems in
the stove (Fig. 6.2).
7 CONNECTIONS
The connections must be set up by a technician
that is qualified and/or authorised by the
Manufacturer.
By the installer the type of cable, with relative
section, to be installed in case of replacement
is: H05RR-F sez.3G0,75
7.1 CONNECTION WITH EXTERNAL AIR
INTAKE
To make the connection with an external air
intake, proceed as follows:
STEP
1
The air vent must be installed in such a way that
it can not be Lineed.
7.2 CHIMNEY CONNECTION
The chimney must be sized so as to guarantee
the draught declared by the Manufacturer.
The stove must be connected to a single flue. It
is forbidden to connect the stove to a flue shared
with other combustion appliances or with hood
exhausts.
The flue must be inspectable for cleaning.
For each type of installation, refer to the
regulations and laws in force in the region where
the product is installed.
Fig. 6.6
Installation must be carried out by a qualified
technician.
7.3 STANDARD INSTALLATION
The tubes shown are not supplied with the unit.
ENGLISH
ACTION
Connect a 50 mm diameter pipe to
the combustion air inlet pipe at the
back of the stove. Note: the pipe must
be no more than 2 m in length.
Fig. 7.1
143