10.3.1 Parameter List
PARAMETER
Stove location
Manual preload
Fan speed zone 1
Pellet mode
Stand-by
Silence buzzer
Enable/disable buzzer
Reset planning
Delayed ignition
Delayed shutdown
Offset zone 1
Thermostat zone 1
10.3.2 "Stove location" function
The geographical location of the stove can be set
manually.
DESCRIPTION
The geographical location of the stove can be
set manually
Manual loading of the auger
You can set the usage mode and fan speed of
zone 1
It is possible to set 10 different combustion
configurations
To enable "stand-by" mode
Silence the buzzer temporarily
Enable/disable the buzzer
To disable planning of switching on and off
Delays switching on
Delays switching off
Room 1 temperature correction
Enable/disable the external thermostat
Fig. 10.7
10.3.3 "Manual preload" function
To preload the stove manually, it must be
connected via Bluetooth.
To manually start the auger (stove off) proceed
as follows:
ENGLISH
SETTABLE
DEFAULT
VALUES
VALUES
Get position
Start; Stop
Start
Manual; Auto;
Auto
1...5 (Manual)
-5...5
On; Off
On
-
Enable;
Disable
Disable
-
15 min...8h;
Start
Start
15 min...8h;
Start
Start
-10.0°C...10.0°C
0.0°C
On; Off
Off
-
0
-
-
Fig. 10.8