ENGLISH
16.4 OUTLINING TABLE OF POSSIBLE
ANOMALIES
TYPE
DISPLAYED TEXT
Air pressure transducer
HW error (AL 14)
High flue gas temperature
warning (AL 40)
Warning
High board temperature
warning (AL 41)
Maintenance request
warning (AL 46)
HW error room probe 1
(AL 04)
HW error smoke extractor
motor (AL 16)
HW error auger motor (AL
17)
Switching on start-up
failure 1 (AL 23)
Switching on start-up
failure 2 (AL 24)
Error
No stabilisation (AL 25)
No flame during
operation (AL 26)
No power during
operation (AL 31)
Main door opening during
start up/work (AL 32)
No pellet (AL 33)
Auger motor torque error
(AL 48)
HW alarm no auger power
supply (AL 49)
178
REASON
No or incorrect connection of the
pressure outlets
Over-temperature read by the flue gas
probe
Over-temperature read by the probe
inside the board
Appliance maintenance period due
date
Faulty or blown probe
Smoke extractor motor faulty or not
working
Auger motor faulty or not working
Pellet hopper empty
Pellet calibration and suction during
switch-on is inappropriate
The switch-on resistor is defective or
not in position
Incorrect reading of flue gas probe
and/or chamber probe
Pellet calibration and suction during
switch-on is inappropriate
The switch-on resistor is defective or
not in position
Incorrect reading of flue gas probe
and/or chamber probe
Pellet calibration and suction during
switch-on is inappropriate
Incorrect reading of flue gas probe
and/or chamber probe
Pellet hopper empty
Incorrect reading of flue gas probe
and/or chamber probe
Temporary blackout
Door, drawer or pellet door were left
open
Pellet hopper empty
Incorrect sensor reading.
Fault in auger motor.
No auger power supply
POSSIBLE SOLUTIONS
Check the connection of the
pressure outlets
Switch off and on again. Seek
the Assistance Service if the
problem continues.
Check that the air passages on
the back of the appliance are
not obstructed
Program the next
maintenance
Seek Assistance Service
Switch it on again or seek
the Assistance Service if the
problem continues
Check all doors are closed
Verify pellet presence in the
tank. Load if needed.
Seek Assistance Service
Check that the doors are
closed. Contact the Service
Department if the problem
persists