Compressed Air Connection En - Abicor Binzel TCS Compact Mode D'emploi

Station de nettoyage
Masquer les pouces Voir aussi pour TCS Compact:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 Putting into operation
6.1 Compressed air connection
1
Compressed air connection (fixed)
Fig. 9
Compressed air connection (fixed and flexible)
1
Compressed air connection (nom. diameter 10)
Fig. 10
Compressed air connection with maintenance unit
Compressed air connection without maintenance unit:
1 Attach the compressed air supply directly to the compressed air connection (1).
The operating pressure should be 6 bar.
If the compressed air supply is under 6 bar, the cutting capacity of the wire cutter and the speed of the pneumatic motor will
be reduced. This will in turn reduce the performance of the torch cleaning station.
Compressed air connection with maintenance unit (optional):
1 Attach the maintenance unit (2) directly to the compressed air connection (1).
NOTICE
• We recommend operating the device with cleaned and oiled compressed air.
EN - 16
1
2
Compressed air connection (flexible)
1
2
2
Maintenance unit (option)
TCS Compact
2