6-2. Meter Functions
.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Lift-Arc TIG
Stick
SS-FCAW
V-Sense
GS-FCAW
Feeder
GS-GMAW
Flashes OCV And Preset
6-3. Mode Switch Settings
.
Stick mode provides the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should the start
require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Lift-Arc TIG
Stick
SS-FCAW
V-Sense
GS-FCAW
Feeder
GS-GMAW
Notes
Meter Reading At Idle
V
14.1
Actual Volts
Preset Amps
V
71.7
Actual Volts (OCV)
Preset Amps
V
71.7
Blank
SS-FCAW With Voltage Sensing Wire Feeder
MIG (GMAW) With Voltage Sensing Wire Feeder
A
85
Actual Volts
A
85
Actual Volts
A
Actual Volts
Process
GTAW − See Section 6-4
SMAW
Meter Reading While Welding
V
A
10.3
85
Actual Amps
V
A
24.5
85
Actual Amps
V
A
24.5
250
Actual Amps
Output Control
Electrode Hot
Electrode Hot
Electrode Hot
Electrode Hot
OM-244 642 Page 23