Technical data 1
POWER SOURCE
Mains voltage ±15% (50-60Hz), V
Minimum generator size, kVA
Minimum short-circuit power, MVA
1)
Fuse, A
Mains current effective, A
Mains current max., A
Power 100%, kVA
Power max., kVA
Power open circuit, W
Efficiency, %
Power factor
Current range, A
Duty cycle 100% 20°C, A
Duty cycle max. 20°C, A/%/V
Duty cycle 100% 40°C, A/V
Duty cycle 60% 40°C, A/V
Duty cycle max. 40°C, A/%/V
Open circuit voltage, V
Sphere of application, C // S
2)
3)
Protection class
Standards, C
Standards, S
Dimensions C (HxWxL), mm
Dimensions S (HxWxL), mm
Weight C / S, kg
POWER SOURCE
Mains voltage ±10% (50-60Hz), V
Minimum generator size, kVA
1)
Minimum short-circuit power, MVA
Fuse, A
Mains current effective, A
Mains current max., A
Power 100%, kVA
Power max., kVA
Power open circuit, W
Efficiency, %
Power factor
Current range, A
Duty cycle 100% 20°C, A
Duty cycle max. 20°C, A/%/V
Duty cycle 100% 40°C, A/V
Duty cycle 60% 40°C, A/V
Duty cycle max. 40°C, A/%/V
Open circuit voltage, V
Sphere of application, C // S
2)
Protection class
3)
Standards, C
Standards, S
Dimensions C (HxWxL), mm
Dimensions S (HxWxL), mm
Weight C / S, kg
1) This equipment complies with EN / IEC61000-3-12:2014 (/ 2011) provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated
data in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that
the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
3) The machine is designed for indoor and outdoor use according to protection class IP23 / IP23S.
IP23S: The machine may be stored but is not intended to be used outside during precipitation unless sheltered
300
3x400
16
3.7
16
10.5
15.4
9.0
10.7
11
87
0.90
MIG
MMA
15-300
15-250
290/28.5
250/30.0
220/25.0
210/28.4
230/25.5
220/28.8
300/25/29.0
250/35/30.0
50-60
S/CE // S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
700x260x735
454x260x735
36.9 / 26
300 Boost
3x208-380
3x380-440
16
16
1.7
3.75
20
16
19.5
10.6
31.6
16.2
7.1
7.0
11.0
10.6
45
16
82
87
0.95
0.95
MIG
MMA
MIG
15-300
15-250
15-300
250/26.5
250/26.5
300/40/29.0
300/40/29.0
200/24.0
200/28.0
200/24.0
210/24.5
210/28.4
210/24.5
300/25/29.0 250/35/30.0 300/25/29.0 250/35/30.0 400/25/34.0
50-60
S/CE // S/CE
IP23S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
IEC60974-1. IEC60974-10 Cl. A
700x260x735
454x260x735
45 / 34
400
3x400
27
6.0
20
17.5
26.0
12.1
18.0
12
89
0.90
MIG
MMA
15-400
15-400
345/31.5
345/33.8
400/65/34.0
400/65/36.0
300/29.0
300/32.0
370/32.5
370/34.8
400/50/34.0
400/45/36.0
65-70
S/CE // S/CE
IP23
IEC60974-1. IEC60974-10 Cl. A
700x260x735
454x260x735
52 / 35
3x208-380
25
25-50
22.0
45.0
8.3
16.7
60
84
0.96
MMA
MIG
MMA
15-250
15-400
15-400
300/29.0
300/32.0
400/30/34.0
400/30/32.0 400/30/34.0
200/28.0
250/26.5
220/28.8
210/28.4
280/28.0
260/30.4
400/20/36.0 400/25/34.0
70-75
S/CE // S/CE
IP23
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
IEC60974-1. IEC60974-10 Cl. A
900x260x735
654x260x735
66 / 49
21
550
3x400
40
9.5
35
27.2
39.2
18.9
27.1
12
90
0.90
MIG
MMA
15-550
15-550
475/37.8
475/39.0
550/60/41.5
550/60/42.0
430/35.5
430/37.2
510/39.5
510/40.4
550/50/41.5
550/50/42.0
75-80
S/CE // S/CE
IP23
700x260x735
454x260x735
53 / 36
400 Boost
3x380-440
25
25-50
11.7
23.5
8.1
16.3
56
88
0.95
MIG
MMA
15-400
15-400
300/29.0
300/32.0
400/30/32.0
250/26.5
220/28.8
280/28.0
260/30.4
400/20/36.0

Publicité