use chemical substances on the stainless steel that contain 25% of nitric acid or
similar substances.
Die-hard stains and rust:
sandpaper or polish with a stainless steel brush. After this operation, wash with
detergents and carefully dry. This intervention may however cause scratches to the
surfaces due to the abrasive cleaning method.
All the cleaning operations, including the disinfection, the rinse and the drying
must be performed diligently, eliminating any water or detergent residue so as
to avoid the spread of bacteria harmful to health.
Parts left to dry with detergent or disinfectant residues may get damaged.
Remove any element from the pavement such as: sponges, rags, detergent or
water residues that may cause accidental slipping and falls.
20_5.Inspection of the parts
Once you've finished the cleaning, disinfection, rinse, and drying operations,
accurately check that all the parts arew perfectly clean and dry and that they are not
damaged or excessively worn out and, if need be, replace them.
Reassemble the completely dry elements and restore electrical power supply. Once
the internal operating temperature has been reached, it is possible to load the
products.
21.Dismantling the cabinet - specialized technician -
The cabinet must be dismantled in compliance to the norms that concern the handling
of wastes foreseen in the individual countries, and in respect of the environment in
which we live in.
This product is considered by the Legislature in force to be a dangerous waste and
therefore its separate waste collection is obligatory and it cannot be treated as
domestic waste nor assigned to a waste dump.
Before dismantling the cabinet, it is necessary to provide for the recovery of the
refrigerant and to remove the lubricant oil.
This product is made up by 75% of recyclable materials.
Materials used in the manufacture:
- Iron pipe and sheet:
- Copper, Aluminium:
- Galvanized steel sheet:
- Expanded polyurethane (R134a):thermal insulation
- Tempered glass:
- Wood:
- PVC
- RIM
- Polycarbonate
It is the user's responsibility to deliver the product intended to be dismantled to
the collection centre specified by the local Authority or indicated by the
Manufacturer for the materials to be recovered and recycled.
All these operations as also transport and waste treatment must be
exclusively performed by specialized and authorized personnel.
05060086 00 20/02/2013
lower frame, uprights, shelves
refrigeration circuit, electrical system and upper strip
lower panels, varnished panels, base structure, decks
and trays
crystal sides
foamed tank side frames
Bumper pads and hand rails
shoulders lower coating
fluorescent light protection and air outlet honeycomb
structure
Chester 2 RTB