Operation
6.4.3 Function test of the rotation break
Basic position of the rotation
break (before the function
test).
As soon as the return in basic position takes less than 2 seconds, the rotation break at the automatic
release must be exchanged unconditional!!! Otherwise exists danger of accidents, because this is a
safety part!
53100415 / 53100380 / 53100416 / 53100284
Ill. F
Raise the automatic release
with one finger and then let it
go.
≥ 2 sec.
Ill. G
Should the return in basic position
takes about 2 seconds, the rotation
break is fully functional.
22 / 26
Ill. H