Warning: You must connect air ducts to both the inlet and outlet, in order to ensure
appropriate IP protection, if you discover moist condensation on the ceiling above the
appliance.
Operation using an air duct results in the loss of some air-fl ow and heat pump ca-
pacity in the system. If you do not connect air duct to the appliance, you must ensure
within the room that no moist or condensation may occur in the space above the ap-
pliance in any case.
Air outlet
Air inlet
Figure 9.1.-3.
The air inlet is not connected to air duct, but the air outlet is. A ≤ 10 m
Recommendation: Use it in case of heat surplus or if it is used in a room with heat
surplus in winter.
Air inlet
Air outlet
Figure 9.1.-4.
The air inlet is connected to an air duct, but the air outlet is not. A ≤10 m
Recommendation: This connection method helps refresh the air within the room dur-
ing summertime.