HPT 200 • HPT 200C
Photovoltaic option (optional)
The control system provides a terminal, which can be connected to a solar panel con-
troller or an inverter. With this option, you are allowed to automatically use electricity
generated from solar energy, provided that it is available on the solar panel controller
or inverter.
You can enable the photovoltaic heater (hereinafter referred to as "PV") via the energy
manager or the photovoltaic inverter, when the control is in ECO or AUTO mode. Then
the heat pump will heat up the appliance to the maximum 62 °C. Electrical heating is
not available with this function, and the display shows the characters "PV".
Installation menu
You can access the installation menu by simultaneously pressing the buttons
Under this menu, you can access test functions and basic settings, which are re-
quired for the maintenance of the appliance, or regulate the basic operational param-
eters of the appliance.
Parameters are named as "I"+character number, and for test function as "T" + charac-
ter number.
Para-
Value
meter
I1
1 or 2
0 (default)
I2
or 1
Off
I3
(default) up
to 20
I4
0 or 1
T1
0 or 1
T2
0 or 1
T3
0 or 1
T4
0 or 1
T5
0 or 1
Note:
If you detect any fault in the operation of the appliance, please, contact our authorised
service station or customer service.
80
Description
1 = Indoor installation. The heat pump extract air from indoor space
2 = Outdoor space. The heat pump is supplied air from outdoor space.
1 = Network controlled power. The heat pump operates using network controlled
power. The controlled power supply lead is connected and the tariff is available.
0 = No controlled power available.
Off = PV (photovoltaic) function disabled (default)
Values from 1 to 20 = Minimum sunny period before the input is activated (in
minutes)
1= Anti-Legionella function On / 0 = Anti-Legionella function Off
1= 30 s compressor test
1 = 30 s electrical heating test
1 = 30 s ventilator speed test 1
1 = 30 s ventilator speed test 2
1= 30 s solenoid valve test
and