6. MAINTENANCE
6.1. Filter Replacement
Filters should be changed regularly, depending on the unit's operating conditions and environment. The filter counter can be set by the user and installer from
6 to 12 months.
1.
Open the filter cover.
Filter References
P/N
Product Name
Pollen Filter MERV 8
699678**
Particle filter MERV 10
699675
Fine Particle Filter MERV 13
699676
Bacteria filter MERV 15
699677
VOC filter MERV 13 with active chacoal
*These filters, sold as accessories, include a pre-filter to be placed on top of the filter, to guarantee its lifespan and efficiency.**Filters MERV 8 and MERV 10
are sold together in a kit (1 unit of each).
25
2.
Remove filters and replace with new ones.
For Configuration A
Left
Right
Standard Top 450
Right only
Right only*
Right only*
Right only*
For Configuration B
Left
Right
Standard Top 450
Left only
Left only*
Left only*
Left only*
EN