5. START-UP / SETTINGS
5.3. Unit behaviour
0-10 V sensor control
Aldes CO
Capteur CO
Nx/Lx
N3/L3
N1/L1
0V
1V
2V
Smart control based on dwelling's humidity
InspirAIR® has an integrated RH sensor in the unit on the dwelling's extracted airstream. A boost to the L3 ventilation level is started when the humidity value
suddenly increases (in variance index above 8 points (not %). The humidity value is checked every minute. In constant airflow mode, the speed change will be
progressive – up to 5 minutes – in order not to disturb the end users in the home. In constant speed mode, the speed change will take effect faster – up to 2
minutes - This boost lasts as long as the humidity value is above the original value with a maximum timer of 60 minutes. After this period, the unit will return to
the previous active speed (manually or automatically or according to a weekly program). If humidity is still high after 60 minutes boost, Boost is activated again
until humidity decreases with the next 60 minutes maximum. This function can be disabled on the remote control.
5.4. Unit Software Update from USB Key
To update the software, follow the steps below:
1) Stop the product (switch it off)
[Open the metal trunking].
2) Insert USB key into USB port
3) Switch the product back on
4) Wait until the LED is green, or approx. 30s for the classic unit
5) Remove USB key
The USB key should contain only the update file supplied by Aldes.
The latest software versions available for the InspirAIR® Top range can be found
5.5. Bypass Function
The bypass is controlled 100% automatically by the unit, according to the season that is registered by the unit.
Seasonal registration
The unit registers the ongoing season (summer or winter) by checking the outside air temperature every hour every day.
- If the average of T is > 19°C or if T max. is > 28°C and T min. > 7°, we are in summer.
- If the average T is < 19°C, or if T max. is < 28°C, we are in winter.
The season is registered 24 hours after starting the unit.
According to the season, the unit will give priority to heating the air in the heating element in winter or cooling the air in summer:
Winter mode
Bypass mode = Setpoint 24°C in the winter cannot be set.
40
35
30
Bypass
25
mode
20
15
10
5
0
5
10
15
Extract Air Tempaterure °C
23
Sensor
Aldes
2
2
0-10 V
(volt)
3V
4V
5V
6V
7V
8V
9V 10V
Prioritized
Heat Recovery
Heat Exchanger Mode
Bypass closed
20
25
30
35
40
Capteur 0-10V proportionnel
Proportional 0-10V Sensor
Flow or Speed
N3/L3
N0/L0
0V
1V
2V
3V
4V
5V
6V
7V
1,5 V
at: https://inspirair-top-software.aldes.com/fr/
Summer mode
Setpoint of 27°C in the summer cannot be set
40
35
Heat Exchanger Mode
30
Bypass closed
25
20
15
10
5
0
5
10
15
Extract Air Temperature °C
0-10 V
(volt)
8V
9V 10V
9,5 V
Prioritized
Cooling/
Bypass*
Bypass
open
* Outdoor Air Temperature is
lower than Extract Air
Temperature
20
25
30
35
40