5. START-UP / SETTINGS
Detailed Menus
Menu
Start-up
Language
Installation Country
Mode Regulation
Configuration Level
Housing Type
Imbalance
Radon Mode
Open Fireplace
Timer Filters
Units
T° Comfort
Certifications
Factory Reset
Quick Adjustment
Sensors
Dry Contact
Real Values
Demo Signal
Allows you to restart the start-up wizard, as was done when the unit was first started up.
This is not a factory reset: values already entered will be proposed again. To perform a factory reset, use
the dedicated function.
Settings
Customize the remote control language for the user and installer.
Allows the unit to adapt the menu to the country in question. Some functions (flow assistant, fire dampers, are
specific to certain countries only).
Allows selection of product control mode:
-In France, only constant flow is possible. Outside France, constant speed is also standard.
-For constant pressure, a change of card is mandatory "constant pressure card kit".
Allows you to set each of the 4 ventilation levels: L0-Vacation / L1-Daily / L2-Pushbutton / L3-Boost. This setting,
available for countries outside France, is in m
Based on the home's characteristics, the unit automatically sets the flow rates for each ventilation level.
This wizard is not available outside France.
Used to adjust an imbalance between air supply and air discharge. This single % value will apply to all fan
speeds. This setting is only available in "self-adjusting" and "constant pressure" control modes.
Allows rapid adjustment of a 15% favourable imbalance between air supply and exhaust, permanently and for
all speeds, based on ventilation recommendations for radon risk. This action can only be activated in constant
flow control mode.
Enables the user, via the remote control menu, to initiate an imbalance of +15% in air supply compared to
exhaust air for 2 hours, the time it takes for an open fireplace to burn at its best.
Allows you to adjust the duration of the filter timer according to the characteristics of the dwelling,
location or occupant's needs: Possible values: from 6 to 12 months.
Customize units C°, m3/h, etc.
Allows you to set the air supply temperature between 16 and 23 degrees when an electric coil is installed.
Allows you to specify the type of dwelling and its possible PassivHaus certification. If so, the unit will adapt its
defrosting strategy
accordingly (no single insufflation motor cut-off allowed).
Aldes recommends the "Non Passiv Haus" configuration if possible.
Resets the unit to factory settings. A new start up will be necessary.
Allows correction of flow rates measured at vents by up to 10%. It is only available for the "self-adjusting"
mode and the L1 and L2 speeds.
Connectivity
Used to set parameters for various 0-10V sensors (see diagram)
Used to set the status of the unit's dry contact. Factory setting: NO (Normally Open).
Alternative value: NC (Normally Closed).
Maintenance
Allows you to examine in real time the various key values of the unit in operation:
(flow setpoints, motor voltages, probe temperatures, etc.) for rapid maintenance diagnostics.
Launches a demonstration phase of the different light signal colours
(for InspirAIR TOP
Premium
only). Leaving this menu stops the demonstration.
Description
3
/h or in %, or in pa depending on the control system.