gnetic compatibility. It must be installed and used in accord with EMC (Electromagnetic
Compatibility) Information.
- The measuring result of this product is only for your reference. If you have any doubt, please
contact your doctor.
1.2. CAUTION
- This equipment may cause radio interference or may disrupt the operation of nearby
equipment. It may be necessary to take mitigation measures, such as reorienting or relo-
cating the equipment or shielding the location.
- The equipment must be used per the requirements of this manual. Failure to properly use
the equipment may result in degraded performance or loss of functionality.
- Mobile and portable RF communications equipment may affect the equipment.
- If the system is installed near or on other electronic devices, please observe to verify nor-
mal operation.
- Other devices may emit harmful radiation or interference that could affect equipment
performance.
- Do not use this product with other accessories than those provided by BewellConnect.
- The received signal may be interfered/disrupted by other equipment operating in this fre-
quency band (i.e. Bluetooth, other non associated access points, microwave ovens, ISM
devices, etc) even if the other equipment complies with its applicable regulations such
as CISPR 11.
- Use this appliance only for the use for which it is designed as described in this manual.
- This appliance may be used for personal use at home and at hospital. Do not use the unit
for other purpose.
- Follow the maintenance instructions specified in this manual.
- Do not attempt to open the device. In case of problems, contact your retailer.
- This device is intended for use by adults only.
- Contact your physician if you require assistance.
- Do not use near flammable anesthetics, or near pressurized oxygen such as in a hyperbaric
chamber, ultraviolet sterilizer or oxygen tent.
- Do not expose the device to strong shocks or vibrations.
- Do not expose this appliance to electric shocks.
- Avoid use near strong electromagnetic forces.
- Generally, portable and mobile RF communications equipment don't affect medical elec-
trical equipment, but it can't be used in the strong electromagnetic interference environ-
ment: TV, microwave oven, mobile phone...
- Do not expose the device to static electricity.
27
BewellConnect - BW-HR1 - User Manual - 042016
- Do not take measurements in a moving vehicle.
- Use this appliance in an ambient temperature range of 5 to 40°C. Do not use this device
in areas with extreme temperatures or humidity. Do not expose this appliance to extreme
temperature conditions > 60°C or < -20°C. Avoid using the device immediately after a sig-
nificant change in temperature or humidity.
- Do not use this appliance at a relative humidity of more than 85%.
- This appliance must always be placed in a clean and dry place.
- Do not expose this appliance to sunlight or water.
- Do not use this appliance outdoors.
- Never drop the appliance.
- Do not operate the device after it has been immersed in liquid.
- Do not use sharp tools to operate any of the buttons.
- The user is an intended operator. All functions of the device that the patient can safely use.
- This appliance is not designed for use by people (including children) with reduced physical,
emotional or mental abilities or those lacking experience or knowledge unless used in the
presence of someone responsible for their security, under surveillance or following instruc-
tions about how to use the appliance.
- It may be unsafe to:
- use accessories, detachable parts and materials not described in the instructions for use
- interconnect this equipment with other equipment not described in the instructions for
use
- disassemble, repair or modify the equipment.
2. USE
Indication for use
The Handheld ECG Monitor is a handheld non-invasive device intended for user to record,
store and transfer Heart Rhythm waveforms and values in hospital and homecare.
2.1. DESCRIPTION
See A page 3
1
Right index finger electrode
2
ECG cable connection: Attach the supplied ECG cable to measure electrical activity of
the heart
3
Right thumb electrode
4
Display screen : shows the date and time, and battery icon. There are five menus to navi-
gate through use of the navigation buttons as described below.
5
6
&
Navigation buttons/Left and Right button: Press buttons to navigate menu items
BewellConnect - BW-HR1 - User Manual - 042016
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bw-hr1

Table des Matières