Tab. 14; Rocker; Fig. 11; Wire Feed Delay Time - Abicor Binzel ABIDRIVE V2 Mode D'emploi

Dévidoir de fil froid tig
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 Putting into operation
6.4.3 2-cycle and interval with torch for controlling the power source via the feed
NOTICE
• A specially equipped intermediate cable assembly is required for this function.
Setting the wire feeder and welding current source to 2-cycle mode.
Move the rocker towards T4 to switch on the wire feed and the welding current source.
On releasing the rocker, the welding process and the wire feed are stopped.
The wire feed can be delayed when starting welding using the parameter dt (0 – 3 sec.).
Wire retraction can be used when stopping welding. The wire retraction time is set using the parameter rE (off – 3 sec.).
The wire retraction feed rate is set using function F2.
The applicable parameter settings can be found in the following table:
Function
Description
dt

Wire feed delay time

rE

Wire retraction time

F2

Wire retraction feed rate

T4

Rocker

Tab. 14

Settings for 2-cycle and 4-cycle mode
t1
2T
Normal
dt
ton
Interval
dt

Fig. 11

Example of 2-cycle mode
6.4.4 4-cycle and interval with torch for controlling the power source via the feed
NOTICE
• A specially equipped intermediate cable assembly is required for this function.
Setting the wire feeder and welding current source to 4-cycle mode.
Move the rocker towards T4 to switch on the wire feed and the welding current source.
Move the rocker again to switch off the welding current source.
The wire feeder shut-down can be set on the 2nd or 4th cycle. Move or release the rocker towards T2 to start or stop the
wire feed.
Stopping the wire feed in the 2nd cycle enhances the end quality of the welding process (wire stops sooner) and prevents
the wire from sticking in the weld pool. The setting is made using function F6 (2 – 4).
The wire feed can be delayed when starting welding using the parameter dt (0 – 3 sec.).
Wire retraction can be used when stopping welding. The wire retraction time is set using the parameter rE (off – 3 sec.).
The wire retraction feed rate is set using function F2.
EN - 16
Explanation of the setting process
 Tab. 9 Display indicators after switching on on page EN-11
 Tab. 9 Display indicators after switching on on page EN-11
 Tab. 10 Display indicators for advanced functions on page EN-13
Switch the welding current source on or off
t2
t=rE
tof
t=rE
TIG cold-wire feeder
T2
m/min
Motor
m/min
Motor
BAL.0415.0 • 2018-10-22

Publicité

Table des Matières
loading

Table des Matières