Taking into operation
Before switching on, it is essential to make sure that the fuse
system for the power supply at the camp site is sufficient
(230 V).
In order to prevent the power cable for the caravan from
overheating (minimum cross-section 3 x 2.5 mm²) the
cable drum must be fully unwound.
To carry out the individual switching commands, the remote
control must always be pointed at the infrared receiver.
Switching on
Press the "On / Off switch" on the remote control to switch
on the air conditioning unit. The most recent settings are
applied.
After switching on, the air circulation fan starts to run.
The compressor activates after a maximum of 3 minutes,
and the blue (cooling) / yellow (heating) LED flashes.
Temperature
If required, adjust the room temperature setting using the "+"
and "–" "Temperature selection buttons".
Mode
Select the required operating mode by pressing the "MODE"
button one or more times.
–
Cooling
–
Heating
–
Automatic (heating or cooling mode depending on the room
temperature setting)
–
Circulated air
When the room temperature that was selected using the
remote remote control is reached in cooling mode, the com-
pressor switches off and the blue LED in the IR receiver goes
out. The air circulation fan continues to run in order to provide
ventilation. If the room temperature setting is exceeded, the
device automatically reverts to cooling mode.
The air is dehumidified during the cooling process. If the
atmospheric humidity is extremely high in the vehicle
when the cooling process starts, moisture can form on the un-
derside of the air distributor. The doors and windows should
therefore be kept closed and the highest fan setting selected.
When the room temperature that was selected using the re-
mote control is reached in heating mode, the compressor
switches off and the yellow LED in the IR receiver goes out.
The air circulation fan continues to run in order to provide ven-
tilation. If the temperature drops below the room temperature
setting, the device automatically reverts to heating mode.
Heating is not possible at an outside temperature of
less than 4 °C, as the heating power drops significantly.
Between 4 °C and 7 °C the device briefly switches to thawing
processes. Heating is possible without restrictions above 7 °C.
Cooling/heating mode and the fan level are selected automati-
cally depending on the room temperature when the unit is in
automatic mode.
In recirculated air mode, the interior air is circulated and
cleaned by the filters. No LED's illuminate on the IR receiver.
16
Fan
Select the required fan level by pressing the "Fan level" but-
ton one or more times.
–
Fan level (not operational in automatic mode)
–
Low
–
Medium (not heating mode)
–
High
Sleep function
When the "Sleep function" is active (cooling mode only),
the interior fan and the exterior fan operate at slow speed
and therefore extremely quietly.
Switching off
Press the "On / Off" button on the remote control to switch
the equipment off. The remote control and the unit are
switched off. The light can still be operated using the
"Ambient lighting" button.
If the air conditioning unit is switched on again, the blue /
yellow LED flashes. The air circulation fan runs and the
compressor switches itself on after a maximum of 3 minutes.
Time
Press the "Time selection button" and set the current time
using the "Time setting" buttons.
The time is always shown in the display (except with Timer
ON / OFF).
The time must be reset after a battery change or daylight sav-
ing time change.
Timer ON / OFF
The air conditioning unit on / off time can be set in advance
from a minimum of 15 minutes up to a maximum 24 hours,
starting from the current time.
To carry out programming, switch on the unit with the remote
control.
Set the required operating mode and room temperature.
Then select TIMER ON or TIMER OFF using the "TIMER
selection buttons". Set the required on / off time using the
"Time setting" buttons (15 minutes – 24 hours) and confirm
with TIMER ON or TIMER OFF.
Press the relevant timer button again to deactivate the timer
function.
Ambient lighting
Independently of the operation of the air conditioning system,
the lighting in the air distributor can be switched on and off
by pressing the „Ambient lighting" button. To dim the light-
ing, press and hold down the "Ambient lighting" button.
Press the button again to activate or deactivate the lighting.
When the lighting is switched on again, the previous setting is
activated.
Reset
The settings on the remote control are reset to "AUTO, 22 °C,
12:00, No timer, No light".
Resend
The most recent settings are transmitted again.