Télécharger Imprimer la page

Jacuzzi PROFESSIONAL Serie Manuel D'installation page 38

Masquer les pouces Voir aussi pour PROFESSIONAL Serie:

Publicité

Les langues disponibles

Les langues disponibles

The same notes are valid as for point A1.
- A4—: start time of third filtering cycle "—".
The same notes are valid as for point A1.
- A5—: end time of third filtering cycle "—".
The same notes are valid as for point A1.
- b0—: method of heating, which can be "On" (always on),
"di" (deactivated), "—" (start time of first heating cycle; no
fractions of hours).
The default setting is "—".
- b1—: end time of first heating cycle "—", which must nec-
essarily be greater than the start time (default=18)
It cannot be modified if b0 = "On" or "di".
- b2—: start time of second heating cycle "—".
The same notes are valid as for point b1.
- b3—: end time of second heating cycle "—".
The same notes are valid as for point b1.
- b4—: start time of third heating cycle "—".
The same notes are valid as for point b1.
- b5—: end time of third heating cycle "—" .
The same notes are valid as for point b1.
When the last of the parameters is confirmed, (b5—), the
time and date parameters are proposed (see the chapter on set-
ting the date and time). If these parameters are correct, to exit
the programming procedure press any key that is not lit (except
"start"), or wait 30 seconds without touching any key ("timeout"
time).
Based on personal needs, you can choose to load one, two or
three scheduled heating or filtering cycles.
For the heating/filtering cycles to be activated, the system
must be in "active" status ("start" key LED on), and the timer must
be in "On" condition (1) (see chapter on setting general system pa-
rameters).
Cycle activation takes place either when the control panel
on the electronic box has been activated, or when the push but-
tons have been enabled.
O
(
)
ZONATOR
OPTIONAL
On request, an ozone generator can be provided which is to in-
stalled on the spa-pak, parallel to the pipes that from the filter re-
turn to the hot-tub (see
The addition of an ozone generator aids in oxidizing the organ-
ic substances that get in the water, and therefore reduces the need
for chemical products for water treatment.
The ozonator works automatically. When the filtering pump
is running, the ozonator comes on for 20 minutes, shuts off for
10 minutes, comes back on for 20 minutes, and so on. These in-
terruptions in operation prevent an excessive build-up of ozone
in closed environment.
Jacuzzi Europe S.p.A. © 2023
1).
The ozonator is however shut off when there are users in the
tub. When a hydromassage pump or the blower are switched on,
this is a clear signal that there are people in the tub. Therefore,
the ozonator is shut off and it stays off for 15 minutes after the
hydromassage pumps and/or blower are shut off.
With intense use of the hot-tub, therefore, the ozonator will
be switched off for long periods.
A
CTIVATION OF HYDROMASSAGE PUMPS
Activation of the hydromassage pumps takes place only via the
push buttons installed near the hot-tub. However this operation
can be performed via the control panel installed on the electronic
box of the spa-pak. This makes it possible to check operation of the
system directly from the spa-pak and to manage the functions even
when the buttons are disabled or have not even been installed.
Activation takes place by modifying the software parame-
ters which can be selected using the "set" key (there are no spe-
cific keys on the display), with the system in "active" status ("start"
key on).
Press and hold the "set" key (9), and the display will show
the message "P1.0" (which stands for hydromassage pump 1).
The keys "+" and "-" will light up, and they can be used to set the
status "P1.1".
Again press the "set" key to memorize this new status and go
on to the next one, i.e. "P2.0" (hydromassage pump 2), which
can be modified to "P2.1".
Press "set" again and also this new value will be memorized,
and you will move on to the third parameter, i.e. "BL.0" (blower),
which can also be changed to "BL.1".
If you press "set" again you will exit the programme. The de-
vices where the status has been changed from 0 to 1 will start
working, provided the following conditions exist:
- the system must be in the "active" condition, i.e. with the "start"
key (3) on and also the "hand" key (2) lit (push buttons disabled).
- if buttons are active ("hand" key off) it is not possible to start the
pumps and/or blower from the control panel (nothing happens
when "set" is pressed).
- if the pumps and/or blower have been started with the proce-
dure described above and the buttons are activated (by press-
ing and holding the "hand" key for about 3 seconds), the devices
in operation will shut down and will not restart automatically
when the control panel is reactivated.
NOTES:
- if parameter P4=0 (see chapter on general system settings), the
devices that were turned on using the procedure described above
remain on continuously until the system is shut off using the "start"
key(3), or with the main switch. If P4 is other than 0, operation
of the pumps and/or blower becomes cyclical, or limited over time,
based on the values set in P4 and P5 (see next chapter on the special
automatic cycle of the hydromassage and/or blower).
- when the system is shut off (with the "start" key (3), via the main
38
Jacuzzi Europe S.p.A. © 2023

Publicité

loading

Ce manuel est également adapté pour:

AlimiaSiennaVirginiaEnjoyProfile proVirtus pro