OPERATION
Settings
4.
Settings
The temperature can be freely selected by the qualified contractor
(see chapter "Installation / Settings").
Factory setting: 60 °C
5.
Cleaning, care and maintenance
f Have the electrical safety of the appliance regularly checked
by an electrician.
Scaling
f Almost every type of water will deposit lime at high tempera-
tures. Limescale will settle inside the appliance and affect its
function and service life. The heating elements must therefo-
re be descaled from time to time. A qualified contractor who
is aware of the local water quality will tell you when the next
service is due.
f Check the taps/valves regularly. You can remove limescale
deposits at the tap outlets using commercially available de-
scaling agents.
f Regularly activate the safety valve to prevent it from beco-
ming blocked e.g. by limescale deposits.
6.
Troubleshooting
Fault
Cause
The water does not heat
There is no power.
up.
The temperature is incor-
rectly adjusted.
The flow rate is low.
The aerator in the taps or
shower heads is dirty or
scaled-up.
Water drips from the
The valve seat is conta-
safety assembly after he-
minated.
ating has stopped.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):
FCR
14
| FCR 28 Si
Remedy
Check the fuses/MCBs in
your fuse box.
Check the temperature
setting.
Clean or descale the ae-
rator or shower head.
Depressurise and isolate
the appliance from the
power supply. Request
your qualified contractor
to attend.
FCR
Nr.: 000000 - 0000 - 000000
Made in Germany
Nr.: 000000 - 0000 - 000000
Made in Germany
www.stiebel-eltron.com