Additional Requirements Of Panic Exit Devices If They Are Used On Smoke Control/Fire Protection Doors; Maintenance Instructions - Häfele DT 710 Instructions De Montage Et De Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
6.5 Additional re-
quirements of panic
exit devices if
they are used on
smoke control/fire
protection doors
6.6 Maintenance
instructions
24
If a door closer is installed to move the door to the closed position again, make sure
that the operation of the door by children and elderly as well as frail people is not
impeded.
The provided locking counterpieces (striking plates) or panelling must be installed in
order to ensure compliance with EN 179.
A sticker with the inscription "Operate lever handle to open" or a pictogram should
be placed on the inside of the door immediately above the operating device or on
the operating device itself (see sample below).
With panic exit devices type "B" (DT 700/DT 710) intended for use on emergency
exit doors opening inwards, a sticker with the inscription "Pull lever handle to open"
or a pictogram should be placed on the inside of the door immediately above the pull
plate. The surface of the pictogram should be at least 8,000 mm² and the colours
white on a green background.
Restriction of the intended use of the DT 700/DT 710 with EN 179:
- Only for single doors
- Escape direction opening inwards or outwards
- Rebated door version
The max. permissible door weight is 200 kg.
The max. permissible deformation of the door leaf to the rebate is 3 mm.
In accordance with EN 1634-1 test report No. DMT-DO-50-229-002 the resistance
time of a single-leaf door construction approx. 65 mm thick made from wood and
wooden materials with thermal insulation EI1 and EI2 is 103 minutes.
The safety features of this product are an essential requirement for its compliance
with DIN EN 179.
No modifications must be made, unless they are described in the instructions.
WARNING
Risk by key inside the profile cylinder!
If there is a key inside the profile cylinder that ist not removed, there is risk
of malfunctions.
> The key of the profile cylinder must always be removed.
> The profile cylinder is for emergency opening only.
In order to ensure that the equipment is usable in accordance with this document,
the following routine maintenance checks must be carried out at least once a month:
• Inspection and actuation of the panic exit device in order to ensure that all
components of the lock are in a satisfactory operating condition.
• The actuation force for releasing the panic exit device must be measured using
a dynamometer and recorded.
• It must be ensured that the locking counterpieces (striking plates) are not blocked
or clogged up.