Detach the panels
1. Loosen the strain relief nuts on the torch lead, work lead, and power cord.
1
1 Power cord strain relief nut
2 Torch lead strain relief nut
2. Lay the power supply on its side.
3. Remove the retaining screws from the bottom of the front and rear panels.
5
2
Raised rib
1
2
Snap
Retaining screw
3
4. Insert needle nose pliers into the opening for one of the snaps, and use the pliers to squeeze it together.
5. Place a blade screwdriver against the raised rib next to the snap, and gently turn the screwdriver to push the panel
away from the base.
Powermax30/Powermax30 XP Field Service Bulletin 805320
1
3
Magnetics Assembly Replacement
Figure 3
3 Work lead strain relief nut
Figure 4
1
Front panel
4
5
Rear panel
3
2
4
3
2
5