H. PHASE (horizontal phase)
Adjusts the horizontal phase when you use the external sync
signal. The initial setting is 10. Adjustable range is from 0 to
255.
SYNC/VD
Switches the signal
1)
output from the Pin 21 on the
CAMERA ADAPTOR connector (26-pin) and from the Pin
7 on the MONITOR connector (D-sub 9-pin).
Selection
Function
Outputs the sync signal.
SYNC
Outputs the VD signal.
VD
GBR/YP
P
B
R
Switches the video signal output from the CAMERA
ADAPTOR connector (26-pin) and the MONITOR
connector (D-sub 9-pin).
Selection
Function
Outputs the GBR signal.
GBR
Outputs the YP
P
signal.
YP
P
B
R
B
R
.................................................................................................................................................................................................................................
1)
You can switch the input and output with the IN/OUT select switch on the rear panel of the CMA-H10 camera adaptor.
Note
If the monitor is equipped with the signal selector, select the
same signal as the GBR/YP
P
setting on the selector.
B
R
FLASH
Sets when you use a flash connected to the FLASH
connector on the rear panel.
Selection
Function
Select this setting when using the camera without a
OFF
flash.
Select this setting when you connect a flash to the
ON
FLASH connector, and use an external frame memory,
etc. Synchronized with the input of an external trigger
signal, a flash is emitted and the WE pulse is output.
Use of the WE pulse with an external frame memory
allows you to capture full-frame still images of an HD
signal.
To select this setting, set FLD/FRM in the PAGE 3/3
menu to FRM.
For details, see the timing chart in flash emission on page
26.