4.
Place the device on a horizontal, solid and
non-flammable surface.
5.
Place the device with a minimum clearance
distance (Figure 8) of:
•
100 cm on the top side;
•
50 cm on the sides;
•
30 cm on the back side;
•
50 cm on the front side.
6.
Do not place the device immediately below a
power outlet.
Wall mounting
WARNING
The wall used for mounting must be made from non-flammable material and
should be able to withstand a minimum temperature of 200 °C.
CAUTION
Make sure to use suitable fastening materials, depending on the surface.
Never block the space between the device and the wall.
1.
Place the device on a vertical and solid
surface. Use a spirit level when placing the
device (Figure 9, pos. 1).
2.
Place the device with a minimum distance
(Figure 9) of:
•
150 cm from the ceiling;
•
30 cm from the side walls;
•
30 cm from the floor;
•
50 cm clearance on the front side.
3.
Do not mount the device:
•
immediately below a socket outlet;
•
on a ceiling or roof.
Figure 8
Figure 9
31