„Sequential" - sequential pump circuit

The sequential pump operation is recommended for long tanks in particular and should be used with at
least three pumps as otherwise no pump sequence can be recognised clearly. The Turbelle® pumps
should be arranged in one line, thus generating a strong wave front with swelling water movement.
Click the "Sequential" button in the "Mode" field.
Set the "Sequential" switching time by clicking 1 to 10 seconds.
Set „Power 1" and "Power 2" pump output in the "Power control" field of one output by clicking the same
value (between 30 per cent and 100 per cent). In order to deactivate wave simulation on each port, the
above has to be set for the other three outputs as well. Set the "Pulse flow" pulse frequency to below 1
second.
"Sequential" - example
Output 1, set "Power 1" to 60 per cent and "Power 2" to 60 per cent.
Output 2, set "Power 1" to 80 per cent and "Power 2" to 80 per cent.
Output 3, set "Power 1" to 100 per cent and "Power 2" to 100 per cent.
Output 4, set "Power 1" to 100 per cent and "Power 2" to 100 per cent.
Set the "Sequential" switching time to 2 seconds.
Connect one pump each to each port of the outputs.
Result:
Pump 1 starts operating with an output of 60 per cent.
Two seconds later, pump 2 starts operating with an output of 80 per cent.
Two seconds later, pump 3 starts operating with an output of 100 per cent.
Two seconds later, pump 4 starts operating with an output of 100 per cent.
Two seconds later all four pumps stop.
Two seconds later, pump 1 starts operating again, et cetera.