„Interval" - low and high tide simulation
"Interval" - example
Output 1, set "Power 1" to 30 per cent and "Power 2" to 100 per cent.
Output 2, set "Power 1" to 30 per cent and "Power 2" to 100 per cent.
Output 3, set "Power 1" to 40 per cent and "Power 2" to 80 per cent.
Output 4, set "Power 1" to 40 per cent and "Power 2" to 80 per cent.
Set "Interval time" time to six hours.
Set "Pulse flow" pulse frequency to 1.5 seconds.
Connect one pump each to each port of the channels.
Result:
Pumps 1 and 2 operate for six hours and vary their output between 30 per cent and 100 per cent.
After six hours, the pumps 1 and 2 are switched off, instead pumps 3 and 4 are operational now and vary
their output between 40 per cent and 80 per cent.
After another six hours, pumps 1 and 2 are switched on again, et cetera.
When activated, the "night mode" function interrupts the pulse operation as soon as the aquarium lighting
goes off; all pumps remain in "Power 1" setting. However, the "Interval" low and high tide simulation
continuous to be operational.
83