Byte
Valve slot
Diagnostic bit Short circuit or open load at valve coil
8
D1.6
D1.7
Table 21: Byte 2
Byte
Valve slot
Diagnostic bit Short circuit or open load at valve coil
2
9
D2.0
D2.1
10
D2.2
D2.3
11
D2.4
D2.5
12
D2.6
D2.7
Table 22: Byte 3
Byte
Valve slot
Diagnostic bit Short circuit or open load at valve coil
3
13
D3.0
D3.1
14
D3.2
D3.3
15
D3.4
D3.5
16
D3.6
D3.7
12.3 Display
12.3.1 LED display
Fig. 13: LEDs on the front plate of the bus coupler
Table 23: Meaning of LEDs on the bus coupler
LED
Signal
Description
UL/DIA
Green
Logic supply U
Red
• Valve driver overload, a message for the channels
• Module failure
• System error (see g 14.2 Malfunctions)
• SREG short circuit
Off
No logic supply U
2)
UQ1
Green
Load supply UQ1 present (UQ1 > threshold)
Red
Undervoltage (12 V < UQ1 < threshold)
Off
Load supply UQ1 not present (UQ1 < 12 V), e.g. emergency OFF
1)2)
UQ2
Green
Load supply UQ2 present (UQ2 > threshold)
Red
Undervoltage (12 V < UQ2 < threshold)
Off
Load supply UQ2 not present (UQ2 < 12 V), e.g. emergency OFF
BF
Red
Bus error:
No physical connection
Participant not yet or incorrectly configured
LNK/ACT 1
Yellow
Active data exchange with network
Green
Connection of the port to the PROFINET IO network active
LNK/ACT 2
Yellow
Active data exchange with network
Green
Connection of the port to the PROFINET IO network active
1)
The UQ2 LED does not light up at the product variant with 7/8" plug.
2)
The switching point (voltage) for LED UQ1 and UQ2 can be changed.
AVENTICS™ PROFINET-IO | R412015162-BAL-001-AF | English
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
A (14)
B (12)
OK, no overload
L
L
Fig. 14: LEDs on input module M8 (left) and M12 (right)
Table 24: LED display on the input modules
LED
Color
10 ... 17
Yellow
Fig. 15: LEDs on output module M8 (left) and M12 (right)
Table 25: LED displays on output module
LED
Color
Meaning
UQ1
Green
Load supply UQ1 present
Red
Diagnosis: Overload / short circuit on controlled output O0,
O1, O2 or O3
Off
Load supply UQ1 not present (e.g. emergency OFF)
UQ2
Green
Load supply UQ2 present
Red
Diagnosis: Overload / short circuit on controlled output O4,
O5, O6 or O7
Off
Load supply UQ2 not present (e.g. emergency OFF)
O0 ... O7 Off
Associated output
LOW level
Yellow
Associated output
HIGH level
12.4 Pin assignment
Table 26: Pin assignment X71 (BUS) and X72 (BUS), 4-pin, D-coded
Pin
Signal
1
TD+
BUS X71
2
RD+
3
TD-
1
2
4
RD-
4 3
Housing
Shield
BUS X72
1
2
4 3
Table 27: Pin assignment of the outputs at output module 8x, 8DO_M12, socket
M12x1
Pin
Signal
1
NC
2
O1, O3, O5
1
2
or O7
5
4
3
3
GND
4
O0, O2, O4
or O6
5
NC
Meaning
Signal level High state
Assignment
Send / (Receive)
Receive / (Send)
Send / (Receive)
Receive / (Send)
Shield protective earth
Assignment
Not connected
Output signal
Reference potential
Output signal
Not connected
28