5. WIRING
• Cut off the mains power supply.
This motor must not be connected to an isolation transformer.
Only the io plate ref: 1811130 may be connected to the J4 io motor.
• Connect the motor and plate assembly
according to the information in the table
below:
1 2 3
Neutral
(Blue)
Earth (yellow/Green)
6. coMMIssIoNING
The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point which
provides greater precision when tilting the slats.
For commissioning using any other io control point, refer to the corresponding guide.
6.1. Identifying setting steps already completed
Only one motor should be powered at a time.
Switch on and follow procedure «a» or «b»
depending on the reaction of the blind:
a) The blind moves briefly
The end limits are set and no
Somfy control point has been stored.
Go to the section entitled 6.5 «Programming the first
Somfy io local control point».
or
b) The blind does not move
Press the up or Down buttons and follow
procedure «c» or «d» depending on the reaction of the
blind: