Steinberg Systems SBS-KW-1000/10O Manuel D'utilisation page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
ACUUMULATE
Press
, to accumulate current weight.
|acc| shows, indicating weight is accumulated. Scale uses displayed weight, so gross or net weight is added
into the same accumulator.
If load is in motion, or negative, or does not return to zero before, |err| shows.
VIEW
Press
,to enter View mode.
Display flashes accumulated weight.
Press
or
, to switch between weight accumulation and total weight.
Press
or
, to exit View mode.
DELETE LAST WEIGHT
Press
, to delete last accumulated weight.
|del| shows, indicating last accumulated weight is deleted. Delete function only deletes the last weight. If last
accumulated weight has been deleted, |err| shows.
EN
CLEAR ALL WEIGHT
Press
and then
, to clear all accumulated weight.
|clr| shows, indicating all weight is cleared.
UNIT SWITCH
Press
or
, to switch unit in between kg, lb, and User Unit.
When unit is kg, kg LED light is on. When unit is lb, lb LED light is on. When unit is User unit, kg and lb are
turned off.
For more information about User Unit, refer to Scale Configuration.
USER SETUP
The user setup enables you to fix several functions of the scale so that it better fits your expectations by
using it. The different parameter can be determined one after another.
ENTERING THE USER SETUP
Press
first and then press
or
REV. V 2016
, to enter user setup menu. SETUP shows.
24
AUTO-OFF TIMING
Press
or
, to enter Auto-Off Timing. Off-- shows.
Press
or
and
, to change timing value.
Auto-Off Timing can be set to: 0(disabled), 5(5min), 10(10min), 15(15min), 30(30min), 60(60min).
Auto-Off function maximizes scale's battery life against people's carelessness not to power off scale when it's
not working. Auto-Off starts countdown timer when there's no action or load is stable.
Any key pressing or motion in load restarts countdown timer.
DISPLAY BRIGHTNESS
Press
or
, to enter Display Brightness. br|| shows.
Press
or
and
, to change brightness value.
Display Brightness can be set to:1(dim), 2(normal), 3(bright).
Dim LED brightness saves battery power.
IDLE MODE TIMING
Press
or
, to enter Idle Mode Timing. Idl-- shows.
Press
or
and
, to change timing value.
Idle Mode Timing can be set to: 0(disabled), 5(5sec), 10(10sec), 15(15sec), 30(30sec), 60 (60sec). It is 30sec
by default.
To maximize battery life, the scale automatically enters Idle Mode, when there's no action or the load is
stable. In Idle Mode,
the scale works in low-power consumption status. Any key pressing or motion in load wakes up the scale
from Idle Mode.
Press
or
, to exit User Setup.
SCALE CONFIGURATION
ATTENTION: The parameters in Scale Configuration are closely related to the scale's
metrology performance. It is NOT recommended to change any parameters unless
you absolutely need to. In case you´re not sure, please contact the customer service to
check if it is necessary to modify these parameters.
REV. V 2016
25
EN

Publicité

Table des Matières
loading

Table des Matières