Télécharger Imprimer la page

Siemens SINAMICS G120C Serie Instructions De Service page 154

Masquer les pouces Voir aussi pour SINAMICS G120C Serie:

Publicité

Configuration du bus de terrain
7.4 Communication via CANopen
Tableau 7- 39 Objets de configuration RPDO - Paramètres de mappage
Nom de l'objet
Indice
Sous-
OD
indice
(hex)
(hex)
1600
Receive PDO 1 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1601
Receive PDO 2 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1602
Receive PDO 3 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1603
Receive PDO 4 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
152
Paramètre
Type de
SINAMICS
données
Unsigned8
p8710.0
Unsigned32
p8710.1
Unsigned32
p8710.2
Unsigned32
p8710.3
Unsigned32
Unsigned8
p8711.0
Unsigned32
p8711.1
Unsigned32
p8711.2
Unsigned32
p8711.3
Unsigned32
Unsigned8
p8712.0
Unsigned32
p8712.1
Unsigned32
p8712.2
Unsigned32
p8712.3
Unsigned32
Unsigned8
p8713.0
Unsigned32
p8713.1
Unsigned32
p8713.2
Unsigned32
p8713.3
Unsigned32
Instructions de service, 01/2011, FW 4.4, A5E02999804A AD
Predefined
Accès en
Connection
écriture/
Set
lecture
1
R
6040 hex
R/W
0
R/W
0
R/W
0
R/W
2
R
6040 hex
R/W
6042 hex
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W