Lift off the battery compartment cover (in the area of the housing slots) from
the bottom part of the battery compartment.
-
Remove the discharged battery/batteries from the battery compartment and
carefully disconnect the battery supply lines (BENNING CM 1-1) from the
battery.
-
Connect the new battery/batteries to the battery supply lines and arrange
them in such a way that they are not crushed between the housing parts
(BENNING CM 1-1). Then, place the batteries into the battery compartment
at the provided place.
-
Lock the battery compartment cover into place on the bottom part and
tighten the screws.
See figure 6a, 6b:
Make your contribution for environmental protection! Do not
dispose of discharged batteries via the household waste.
Instead, return them to a collecting point for discharged
batteries or spezial waste. Please look for information in your
community's facilities.
9.4 Calibration
To maintain accuracy of the measuring results, the device must be recalibrated
in regular intervals by our factory service. We recommend recalibrating the
device once a year. For this purpose, send the device to the following address:
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Service Center
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
4 mm safety measuring line ATL 2 (BENNING CM 1-2)
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth ( ) and measuring category:
1000 V CAT III, 600 V CAT IV,
-
Maximum rated current: 10 A,
-
Protection class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Ambient conditions:
Barometric height for measurements: max. 2000 m,
Temperature: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Use the measuring lines in perfect condition and according to these
operating instructions only, as otherwise the protection provided might be
impaired.
-
Replace the measuring lines, if the insulation is damaged or if the conductor/
connector is interrupted.
-
Do not touch the bare contact tips of the measuring lines. Only touch the
area intended for your hands!
-
Insert the bent terminals into the testing or measuring device.
11. Environmental protection
At the end of product life, dispose of the unserviceable device via
appropriate collecting facilities provided in your community.
05/ 2008
Battery replacement
BENNING CM 1‑1/ 1‑2
14

Publicité

loading