9 COM jack, common jack for voltage/ resistance measurements and
continuity test,
J Opening lever, for opening and closing the current clamp,
K Bulge for current clamp, protects against contact with conductor,
L Measuring clamp, for clamping on the single-wire live conductor,
This is what the automatic polarity indication for DC voltage refers to
1)
5.
General information
5.1 General information on the current clamp multimeter
5.1.1
The digital display 1 is a 3½-digit LC display with a font size of 14 mm
and a decimal point. The highest numerical value to be displayed is
2000.
5.1.2
The polarity indication 2 works automatically. Only a polarity contrary
to the jack definition is indicated with "-".
5.1.3
The range exceedance is indicated by " 0L" or "- 0L" and partly by an
acoustic warning.
Attention, no indication and warning in case of overload!
5.1.4
Measured value storage "HOLD": Press the "HOLD" key 4 to store the
measuring result. At the same time, the display shows the "H" symbol.
Press the key again to switch back to the measuring mode.
5.1.5
The MAX key function 5 automatically determines and stores the
highest measured value. By pressing the key, the following values are
displayed:
"MAX" shows the highest stored value. The continuous determination of
the MAX value can be stopped or started by pressing the "HOLD" key
4. Press the "MAX" key to switch back to normal mode.
5.1.6
Press the 6 V~/ V or Ω/
sliding switch position (see indication on the display).
5.1.7
The nominal measuring rate of the BENNING CM 1-1 is 2.5
measurements per second for the digital display. The nominal measuring
rate of the BENNING CM 1-2 is 1.5 measurements per second for the
digital display.
5.1.8
The BENNING CM 1-1/ 1-2 can be switched on or off by means of the
sliding switch 7. Switched off: position "OFF".
5.1.9
The BENNING CM 1-2 is switched off automatically after approx. 10
minutes (APO, Auto-Power-Off). It is switched on again if a key or the
sliding switch is operated. A buzzer tone indicates that the device is
switched off automatically. The BENNING CM 1-1 is not provided with
an APO function.
5.1.10 Temperature coefficient of the measured value: 0.2 x (stated measuring
accuracy)/ °C < 18 °C or > 28 °C, related to the value for the reference
temperature of 23 °C.
5.1.11
The BENNING CM 1-1 is supplied by means of a 9 V block battery (IEC
6LR61).
The BENNING CM 1-2 is supplied by means of two integrated 1.5 V
micro (AAA) batteries (IEC LR 03).
5.1.12 If the battery voltage falls below the specified operating voltage of the
BENNING CM 1-1/ 1-2, a battery symbol appears on the display.
5.1.13 The battery life is approx. 580 hours for the BENNING CM 1-1 and
approx. 200 hours for the BENNING CM 1-2 (alkaline battery).
5.1.14 Dimensions of the BENNING CM 1-1:
(L x W x H) = 180 x 70 x 42 mm
Weight: 200 g
Dimensions of the BENNING CM 1-2:
(L x W x H) = 190 x 70 x 38 mm
Weight: 225 g
5.1.15 The safety measuring lines are designed in 4 mm plug-in technology.
The enclosed safety measuring lines are explicitly intended for the
nominal voltage and the nominal cuurent of the BENNING CM 1-2.
5.1.16 Largest clamp opening: 30 mm
5.1.17 Largest cable diameter: 27 mm
6.
Ambient conditions
-
The BENNING CM 1-1/ 1-2 is intended for measurements under dry
ambient conditions,
-
Maximum barometric height for measurements: 2000 m,
-
Overvoltage category / installation category: IEC 60664-1/ IEC 61010-1
→ 600 V category III,
-
Contamination class: 2,
-
Protection category: IP 30 (DIN VDE 0470-1 IEC/ EN 60529)
3 – first index: protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm
0 – second index: no protection against water,
05/ 2008
key to select the secondary function of the
BENNING CM 1‑1/ 1‑2
10