Télécharger Imprimer la page

probst VZ-H-UNI-KV Instructions D'emploi page 41

Masquer les pouces Voir aussi pour VZ-H-UNI-KV:

Publicité

Les langues disponibles

Les langues disponibles

Installation
4.2
Hydraulical connection
The two hydraulic hoses (for opening and closing the device) on the carrier must be screwed onto
the two hydraulic connections on the valve block of the device (VZ-H-UNI).
A second control circuit is necessary if a rotating motor is integrated at the VZ-H-UNI.
In accordance with the enclosed hydraulic wiring diagram a unblockable non-return valve is built
into the (VZ-H-UNI) circuit to prevent, that the kerb stone does not fall down, loss of pressure.
Is there only one (two) hydraulic circuit on the lifting apparatus, you can split one of the circuits by
using a electromagnetic valve ELMV.
The hydraulic hoses must be free of breaks and abrasion. Take care that there are no outstanding
edges, where the hoses could hook in.
G
A faultless and reliable in operation function of the device (VZ-H-UNI-BV) is ensured, if the
following values are adjusted.
Installed load:
Conveying line
Support frame:
Line pressure
Support frame:
Back pressure
in return flow:
To avoid disorders and failed functions it is absolute necessary, for every commissioning of the
device
(VZ-H-UNI), to check the correct connection of the hydraulic hoses!
51600031-002
optimal
25 in l/min
200 bar
0 bar
12 / 22
minimal
15 in l/min
200 bar
0 bar
maximal
75 in l/min
250 bar
5 bar
GB