- wash all parts with detergent being sure that all visible
residue and product layers are mechanically removed,
using a brush if necessary;
Disinfection should be carried out using sanitising prod-
ucts.
- soak all components for approx. 20 minutes in a container
filled with the previously prepared sanitising solution;
- reinstall the feeders and the water funnels;
- reinstall the powder deposit drawers and the powder
funnels after thoroughly drying them.
After reinstalling all parts the following is however
required:
- add a few drops of the sanitising solution in the mixer;
- using the cleaning function, thoroughly rinse all compo-
nents to ensure that all residue of the detergent solution
is removed.
MAINTENANCE OF THE BREWER UNIT
As well as cleaning every week and/or every 1,000 selec-
tions, the brewer filter and gasket must be replaced every
25000 selections, even if apparently still efficient.
Every 100,000 selections the brewer unit must be disas-
sembled completely to thoroughly clean all parts and
replace the worn ones.
Important notice!!
Should the unit need to be removed completely, it must not
be held by the cylinder or by the filter holder.
Fig. 24
© by N&W GLOBAL VENDING SpA
All manuals and user guides at all-guides.com
MAINTENANCE OF THE BOILER
According to the hardness of the water and the number of
selections made, a periodic descaling of the boiler is
necessary.
This operation should be carried out by qualified
technicians only.
To descale the boiler, it is necessary to remove it from the
machine.
For descaling use only biodegradable, non-toxic and mild
products.
Thoroughly rinse all parts before reassembling.
When reassembling make sure that:
- the electrical contacts (terminals, fastons etc.) are thor-
oughly dry and correctly connected;
- the safety and anti-boiling thermostats are suitably posi-
tioned and fastened;
- the hydraulic connections are correctly made.
IMPORTANT NOTICE!!!
If for any reasons the heating system of the boiler is
operating without water, check the correct function-
ing of the boiler temperature sensor before restarting
the machine.
If dry heating continues until the safety thermostat is
activated (see hydraulic system) the boiler temperature
sensor could be damaged permanently and therefore
need to be replaced;
a thorough check of all components of the system (pump,
boiler heating element, tubing etc. in indispensable in any
case.
28