- in order to remove the water funnel, rotate the green
ring nut anti-clockwise;
pay special attention to closing it fully during
reassembly;
- in order to remove the impellers, block the disk fitted
on the mixer shaft with a finger (see Fig. 9 and 10).
Fig. 9
SUSPENDING FROM USE
If for any reason the machine is switched off for a period
exceeding the use-by date of the products, the following
will be necessary:
- completely empty the containers and thoroughly wash
them with the sanitising products used to clean the
mixers;
- completely empty the water tank.
© by N&W GLOBAL VENDING SpA
All manuals and user guides at all-guides.com
CLEANING THE FRESH-BREW UNIT
Periodically, according to the operating condition of the
machine and in any case at least weekly, it will be neces-
sary to clean all parts that come into contact with the drink.
Washing can be carried out in a dishwasher (60°C max) or
using normal dishware detergent.
The parts to be cleaned are indicated in the figure 11.
Fig. 10
Fig. 11
1 - Upper cover
2 - Mixer feeder
3 - Upper valve
4 - Pressure cylinder
5 - Brewing chamber
6 - Chamber grip
7 - Filter
8 - Filter support
9 - Filter support spring
10 - Scraper