Télécharger Imprimer la page

Keysight U2741A Guide D'utilisation page 25

Multimètre numérique modulaire usb

Publicité

Les langues disponibles

Les langues disponibles

Instrument Configuration
55-Pin backplane connector pin configuration
The 55-pin backplane connector is used when the U2741A module is inserted into
the U2781A USB modular instrument chassis. For more details, refer to the
Keysight U2781A USB Modular Instrument Chassis User's Guide.
GND
GND
NC
NC
GND
TRIG3
TRIG4
GND
nBPUB
CLK10M
NC
NC
11
10
Figure 1-1
Table 1-1
SSI connector pin description
SSI timing signal
GND
NC
VBUS
USB_D+, USB_D–
TRIG0~TRIG7
+12 V
nBPUB
Keysight U2741A User's Guide
GND
GND
GND
NC
NC
NC
GND
TRIG2
ND
TRIG5
GND
TRIG6
GND
STAR_TRIG
GA2
NC
NC
NC
9
8
7
55-pin backplane connector pin configuration
GND
GND
GND
NC
NC
NC
TRIG1
GND
TRIG0
GND
TRIG7
GND
GA1
GA0
NC
NC
NC
NC
6
5
4
Functionality
Ground
Not connected
USB bus power sensing input
USB differential pair
Trigger bus
+12 V power with 4 A current
USB backplane input detect
Getting Started
GND
GND
GND
VBUS
GND
USB_D–
GND
GND
USB_D+
+12 V
+12 V
GND
+12 V
+12 V
+12 V
+12 V
+12 V
+12 V
3
2
1
1
F
E
D
C
B
A
25

Publicité

loading