HPO 24-45, 24-60, 24-80, 24-100
Part Number
Model
recommended battery bank (Ah)
Input
Voltage
Frequency
Input current consumption
230/115VAC
Recommended power for a generator
Power factor
Efficiency
Input fuses
Output
Number of battery bank
Connection on throaded rods
Total rated current (+/-7%) /
Rated power
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
Mosfet splitter and fuse
Peak to peak ripple and noise
Automotive output fuse mounted in
series in minus pole -BAT
Alarms
Isolated CAN-BUS communication
Environment
Cooling
Sound level
Operating temperature at 230VAC
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE / EMC
CE / Security
Protections
Options
Temperature probe
Analog and digital displays
Parallel mouting
Remote control touch screen display
Remote control
HPO24-45
24V/45A
300-600Ah
6.0/16.0A
1600W
2 x 20A 250V (6,3x32)
(F1/F2)
3 (including one for the engine): +BAT E, +BAT 1, +BAT 2 (integrated Mosfet splitter ) and 1 -BAT
45A/1282W
IU or IUoU through internal dip switches (Boost, Absorption, Floating – factory setting).
Lead sealed as factory setting - Gel, AGM, Calcium Lead, LiFePO4, DC power-supply mode, etc.
2 x 30A/32V
Rated charge from -20°C to +50°C, derating above 50°C. Automatic charger switch off above 60°C ;
- Against leaking input surges by VDR rupture (voltage dependent resistor) - Not covered by warranty
- Against output polarity reversal by fuse rupture
- Against short-circuit and surge
- Against abnormal overheating by cutting off the charger
Output voltage compensation : -36mV/°C (2,8m : STP-UNI-2.8 or 5m : STP-UNI-5)
HPO24-60
24V/60A
500-800Ah
from 90 to 265VAC single-phase automatic
from 47 to 65Hz automatic
9.0/20.0A
2100W
1
87% typical
2 x 25A 250V (6,3x32)
(F1/F2)
Each bank can be used individually and deliver the rated current
M6
60A/1710W
Selectable automatic Refresh
Specific request on demand
28,8 VDC for Lead sealed battery (factory setting)
27,6 VDC for Lead sealed battery (factory setting)
< 1% (at rated conditions)
< 1% (at rated conditions)
3 x 25A/32V
Low battery (+BAT1) alarm and "charger fault" with dry contacts
By default
Electric fan controlled in temperature and current
< 50dBa at 1m
automatic restart when temperature decreases
From -20°C to +70°C
up to 96% without condensation
Painted Aluminium
270 x 360 x 130 mm
/ 6.8kg
4 x M6 round head screws
IP23
Water-repellent varnish
EN61204-3
EN60335-2-29
1 ammeter: charger current - Please consult us
Up to 4 units with balancing and charge control (KIT-HPO-LINK)
UNI-DISPLAY-R
Remote control (G-ON/OFF-R)
HPO24-80
24V/80A
700-1000h
11.0/20.0A
2800W
2 x 32A 250V (6,3x32)
80A/2280W
100A/2850W
4 x 25A/32V
270 x 410 x 130 mm
HPO24-100
24V/100A
800-1300Ah
15.0/30.0A
3520W
(F1/F2)
5 x 40A/32V
/ 9.0kg
46