5 TECHNICAL SPECIFICATIONS
HPO 12-90
Part Number
Model
recommended battery bank (Ah)
Input
Voltage
Frequency
Input current consumption
230/115VAC
Recommended power for a generator
Power factor
Efficiency
Input fuses
Output
Number of battery bank
Connection on throaded rods
Total rated current (+/-7%) /
Rated power
Charging curve
Battery type
Boost voltage
Floating voltage
Regulation tolerance before output
Mosfet splitter and fuse
Peak to peak ripple and noise
Automotive output fuse mounted in
series in minus pole -BAT
Alarms
Isolated CAN-BUS communication
Environment
Cooling
Sound level
Operating temperature at 230VAC
Storage temperature
Relative humidity
Casing
Material
Dimensions (length, height, depth) /
Weight
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE / EMC
CE / Security
Protections
Options
Temperature probe
Analog and digital displays
Parallel mouting
Remote control touch screen display
Remote control
3 (including one for the engine): +BAT E, +BAT 1, +BAT 2 (integrated Mosfet splitter) and 1 negative -BAT
Each bank can be used individually and deliver the rated current
IU or IUoU through internal dip switches (Boost, Absorption, Floating – factory setting).
Lead sealed as factory setting - Gel, AGM, Calcium Lead, LiFePO4, DC power-supply mode, etc.
Low battery (+BAT1) alarm and "charger fault" with dry contacts
Rated charge from -20°C to +50°C, derating above 50°C. Automatic charger switch off above 60°C ;
- Against leaking input surges by VDR rupture (voltage dependent resistor) - Not covered by warranty
- Against output polarity reversal by fuse rupture
- Against short-circuit and surge
- Against abnormal overheating by cutting off the charger
Output voltage compensation : -18mV/°C (2,8m : STP-UNI-2.8 or 5m : STP-UNI-5)
HPO12-90
12V/90A
700-1200Ah
from 90 to 265VAC single-phase automatic
from 47 to 65Hz automatic
6.0/16.0A
1600W
1
87% typical
2 x 20A 250V (6,3x32)
(F1/F2)
M6
90A/1282W
Selectable automatic Refresh
Specific request on demand
14,4 VDC for Lead sealed battery (factory setting)
13,8 VDC for Lead sealed battery (factory setting)
< 1% (at rated conditions)
< 1% (at rated conditions)
4 x 30A/32V
By default
Electric fan controlled in temperature and current
< 50dBa at 1m
automatic restart when temperature decreases
From -20°C to +70°C
up to 96% without condensation
Painted Aluminium
270 x 360 x 130 mm
/ 6.8kg
4 x M6 round head screws
IP23
Water-repellent varnish
EN61204-3
EN60335-2-29
1 ammeter: charger current - Please consult us
Up to 4 units with balancing and charge control (KIT-HPO-LINK)
UNI-DISPLAY-R
Remote control (G-ON/OFF-R)