Installation manual for WiPro III
1.9.2 Installing the wireless magnetic contacts
Choose the places where you want to install the wireless magnetic contacts.
The transmitters can be installed both on the window and the frame (see diagrams
on Page 8). The distance between the transmitter (Diagram 3, Part A, Page 6)
and magnet (Diagram 3, Part B, Page 6) can be around 22 mm. A larger distance
a ctivates the transmission process (LED lights up briefly. Diagram 4, C) and triggers
the alarm when the system is activated.
Before installing the wireless magnetic contacts, carry out a range test using the
adhesive pads.
I n order to do so, fix the transmitter which is already assigned and the magnets
to the places you have chosen using adhesive tape and follow the instructions
under 1.9.3.
The contact surface must be clean, dry and free of grease. Treat with suitable
cleaning agent beforehand.
GB
Do not use on surfaces at temperature below 15 °C.
The adhesive pads reach their final strength after approx. 24 hours.
If installed on the rear storage locker, use the mounting adapter
(Item no. 100428 black or 100729 white) to optimize the transmission
and bridge larger gaps.
1.9.3 Range test / Diagnostics mode
B riefly press the button "B" on the central unit (Diagram 1 Page 6). The status LED
on the cable assembly starts to flash. WiPro III is now in Diagnostic mode.
If there is no acoustic acknowledgement tone, the transmitter is not assigned
( repeat 1.8) or shielded by metal parts. In this case, choose another place to mount
the transmitter or use the mounting adapter (Item no. 100428 or 100729).
To terminate Diagnostics mode, briefly press the button "A" again.
The LED goes out.
1.9.4 Installing the wireless gas alarm (accessory)
Choose a suitable place to mount the wireless gas alarm.
The place where it is mounted should not be in the direct vicinity of the heater
outlets or where there are lead-acid batteries. Mounting it in the direct vicinity
of strong cleaning agents, petrol and other fuels should also be avoided.
The ideal height of installation is at the lowest point of the vehicle just above the
floor (approx. 10 – 20 cm).
Now carry out a range test with the wireless gas alarm, as described under 1.9.3.
Mount the wireless gas alarm using the template in the wireless gas alarm manual
and connect the supply voltage. (brown = +12 V / white = earth)
The central unit acknowledges every transmission process received from
an assigned transmitter with an acoustic signal.