EN
Slide the DIP switches to the position shown in the table below to set the charging program for the respective
type of house battery.
Table 6: Charging curve configuration
DIP switch po-
sition (gray)
18
Function
Charging
Max. voltage (U
program
12 V
14.2 V
Lead gel bat-
teries
14.4 V
Wet batteries
14.7 V
AGM/1 bat-
teries
14.7 V
AGM/2 bat-
teries
14.5 V
LiFePO4/1
batteries
14.5 V
LiFePO4/2
batteries
14.2 V
LiFePO4/3
batteries
)
Float voltage (U
abs
24 V
12 V
28.4 V
13.5 V
28.8 V
13.8 V
29.4 V
13.6 V
29.4 V
13.6 V
29 V
13.8 V
29 V
OFF
28.4 V
13.6 V
)
Max. desulfation volt-
float
age
24 V
12 V
27 V
OFF
27.6 V
OFF
27.2 V
OFF
27.2 V
15.6 V
27.6 V
OFF
OFF
OFF
27.2 V
OFF
24 V
OFF
OFF
OFF
31.2 V
OFF
OFF
OFF