Télécharger Imprimer la page

Allmatic BIOS1 24V Mode D'emploi page 37

Masquer les pouces Voir aussi pour BIOS1 24V:

Publicité

Les langues disponibles

Les langues disponibles

The opening photocell has the following functioning:
Opening: stops the movement and waits until the beam is freed, then moves in opening.
Closing:
– ph.2. = 0 stops the movement and waits until the beam is freed, then moves in opening.
– ph.2. = 1 no intervention.
8.
PHOTOCELLS TEST TP.h.
By enabling this function, before each movement starting from steady automation, the control unit does a functional check of the photocells. The check
will not be done in case of fast movement after the intervention of a safety device. Follow paragraph 4.1 for the connections of the photocells.
9.
SAFETY EDGE TYPE ED.M.
The control unit can work with two different types of safety edges:
ed.m. = 0 mechanical with normally closed contact.
ed.m. = 1 resistive edge 8,2K
10. OPERATION MODE OF SAFETY EDGE iE.D.
To allow the installation of the safety edges in both the directions of movements, it is possible to choose 2 different functionings:
ie.d. = 0 only in closing with total inversion of the movement.
ie.d. = 1 both directions of movements, stop and short inversion to free the obstacle.
11. SAFETY EDGE TEST TE.D.
By enabling this function the control unit does a functional check of the safety edge. This function is used if the edge connected to the control unit has
an electronic self test (exp. radio edge R.CO.O). Connect the test contact of the edge to the power supply of the trasmitter of the photocells (paragraph
4.1) ad enable the self test with low voltage 0Vdc (for the compatibility follow the instruction of the safety edge with the electronic self test).
12. PARTIAL OPENING LP.o.
Partial opening can be performed only starting from a closed position. The parameter sets the opening like a percentage of the total stroke.
13. AUTO RECLOSING TIME FROM PARTIAL OPENING TP.C.
Active when the automation is in the partial opening, it automatically closes after tp.C. seconds. In this phase the display shows -TC with the blinking
dash, that during the last 10 seconds will be replaced by the count down.
14. FLASHING LIGHT OUTPUT MODE FP.r.
It is possible to choose 2 different functionings for the blinker output:
fp.r. = 0 fixed output. It will be necessary to connect a self flashing blinker (B.RO LIGHT 24 Vac).
fp.r. = 1 flashing light output. It will be necessary to connect a fix light blinker (B.RO LIGHT FIX 24 Vac).
15. PRE-FLASHING TIME TP.r.
Pre-flashing before each movement in both directions, tp.r. seconds of pre-flashing.
16. COURTESY LIGHT SETTINGS FC.Y.
The control unit has 4 different functionings for the courtesy light:
fC.y. = 0 the light switches off at the end of a movement after tC.y. seconds.
fC.y. = 1 the light switches off only with closed automation after tC.y. seconds tC.y.
fC.y. = 2 lighted on for tC.y. seconds from the beginning of a movement, indipendently on the conditions of the automation (the light could
switch off before the end of the movement).
fC.y. = 3 open automation light - the light switches off immediately when the automation reaches the closed position.
fC.y. = 4 open automation light with proportional blinking:
– Opening: slow blinking.
– Closing: fast blinking
– Opened: light on
– Closed: light off.
– Stopped: 2flash + long wait + 2flash + long wait +...
17. COURTESY LIGHT TIME tC.Y.
Activation time of the courtesy light.
18. DEAD MAN DE.A.
During the DEAD MAN functioning mode the automation moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During the dead man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for STOP.
19. SETTING THE CYCLES THRESHOLD FOR ASSISTANCE REQUEST SE.R.
It is possible to set a number of cycles before the request of assistance. Once the limit is reached, the next cycles will be done with a fast blinking
(only if fp.r. = 1 ).
20. CONTINUOUS FLASHING LIGHT FOR ASSISTANCE REQUEST SE.F.
Once the limit se.f. is reached the flashing light will blink also with the automation closed to show the request of assistance.
21. MODE OF USE OF THE R1 OUTPUT RI.M.
This parameter allows to select the functioning of the R1 card (optional):
rI.m. = 0 The output is disabled.
rI.M. = 1 Courtesy light: the NO contact (without voltage) of the R1 card has the same functioning of the output OGL.
rI.m. = 2 Ecomode: it enables the ECOMODE function and the NO contact of the R1 card is used to cut the power supply of the 24Vdc accessories.
See chapter 10.
22. PRESSURE OF THE MOTOR IN CLOSED POSITION MP.r.
This function is used to keep the pressure of the motors on the mechanical stop, performed only with closed automation. The control unit performs 1
minute of closing every mp.r. minutes to keep the pressure on the mechanical stops.
6-1622400 rev. 5
All manuals and user guides at all-guides.com
.
ITA
04/06/2019
ENG
FRA
ESP
17/20

Publicité

loading