9 - CHANGE PARAMETERS - ADVANCED MENU
This menu allows a more detailed setting of some parameters.
To enter the ADVANCED MENU, press and hold the "MENU" button for at least 5 seconds.
To change the parameters, proceed as described for the BASIC MENU.
WARNING - after 2 minutes of inactivity, the control unit exits automatically from the menu.
PARAMETERS
Intervention mode of the current sensor:
0 = disabled.
sn
m
1
1 = complete (limit switch and obstacle)
.
.
2 = only obstacle detection in any point of the stroke.
3 = only end of the movement in any point of the stroke.
sI
t
2
Intervention time of the current sensor.
.
.
sd
t
3
The disabling time of the current sensor during the start of the motor.
.
.
Acceleration ramp amplitude:
0...20 = ramp amplitude.
ur
a
4
.
.
SSr = single step at 50% of the running speed.
Hsr = single step at 100% of the running speed.
dr
a
5
Deceleration ramp amplitude.
.
.
Functioning of closing photocell (PH1) moving from closed:
sp
h
6
0 = check PH1.
.
.
1 = the automation opens also with PH1 obscured.
Functioning of opening photocell PH2
ph
2
7
0 = enabled in opening and closing.
.
.
1 = enabled only in opening.
Photocells test:
0 = disabled.
tp
h
8
1 = enabled PH1.
.
.
2 = enabled PH2.
3 = enabled PH1 and PH2.
Safety edge type:
ed
m
9
0 = contact (NC).
.
.
1 = resistive (8k2).
Operation mode of safety edge:
0 = working only in closing with inversion of movement.
ie
d
10
.
.
1 = stops the automation (both opening and closing) and free the obstacle
(short inversion).
Safety edge test:
te
d
11
0 = disabled.
.
.
1 = enabled.
LP
o
12
Partial opening.
.
.
TP
C
13
Auto reclosing time from partial opening (0 = disabled).
.
.
Blinker output mode:
FP
R
14
0 = fix.
.
.
1 = blinking.
TP
R
15
Pre-flashing time (0 = disabled).
.
.
Courtesy ligth settings:
0 = at the end of the movement for a TC.Y. time.
1 = on if the automation is not closed + TC.Y. time.
FC
Y
16
.
.
2 = on if the courtesy light timer (TC.Y.) is not expired.
3 = open automation light on/off.
4 = open automation light with proportional flashing.
tC
y
17
Courtesy light time.
.
.
Dead-man:
de
a
18
0 = disabled.
.
.
1 = enabled.
6-1622400 rev. 5
04/06/2019
All manuals and user guides at all-guides.com
DESCRIPTION
1
2
2
ITA
ENG
FRA
DEFAULT
CUSTOM
2
1
2
15
10
10
1
0
0
0
0
0
30
0
1
0
0
180
0
ESP
UP
DOWN
MENU
SS
MIN
MAX
UNIT
0
3
1
10
x 100ms
0
30
x 100ms
0
20
x 35ms
0
20
x 35ms
0
1
0
1
0
3
0
1
0
1
0
1
0
100
%
0
900
s
0
1
0
10
s
0
4
0
900
s
0
1
15/20