Télécharger Imprimer la page

Hypertherm Powermax45 Mode D'emploi page 3

Remplacement de la base en plastique
Masquer les pouces Voir aussi pour Powermax45:

Publicité

Les langues disponibles

Les langues disponibles

Introduction
Purpose
This field service bulletin describes the steps necessary to replace the plastic base on the
Powermax45.
Tools and materials needed
Assorted Phillips
Pins, wires, or swabs with a 2 mm (0.09 inch) diameter
228258 Kit contents
Part number
001983
075711
110648
110662
110649
210210
Powermax45
Field Service Bulletin
All manuals and user guides at all-guides.com
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be performed
by a qualified technician.
See the Safety and Compliance Manual (80996C) for more safety
precautions.
and TORX
screwdrivers
®
®
Description
Plastic base for Powermax45
Machine screw: M4 x 12
Data plate label (preapplied to base) that is specific to the
power supply configuration:
• 200 – 240 V CSA data plate
• 230 V CE/CCC data plate
• 400 V CE/CCC data plate
• 480 V CSA data plate
805830
Plastic Base Replacement
Quantity
1
6
1
3

Publicité

loading

Ce manuel est également adapté pour:

Powermax45 xp