Proceed as follows.
Turn off the gas supply tap.
1)
Open the hatch (A).
2)
Undo the locking screw (B).
3)
Set the bush (C) at the distance (D) shown in
4)
the table.
Tighten the screw (B).
5)
Important
After making the setting, seal the screw with
paint.
Close the hatch (A) when the operation is
6)
complete.
GB

INSTRUCTIONS AND WARNINGS FOR THE REPLACEMENT OF PART

Important
Before carrying out any replacement proce-
dure, activate all the safety devices provi-
ded and decide whether staff at work and
those in the vicinity should be informed. In
particular, turn off the gas supply tap, cut
off the electricity supply using the master
switch and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
3329640_inst_GB

ADJUSTING BURNER PRIMARY AIR

A

REPLACING PARTS

GAS family
II (G25/20-25 mbar)
II (G25.1/25 mbar)
II (G25.3 - 25 mbar
II (G20/20-25 mbar)
III (G30-G31/50 mbar)
III (G30/29 mbar)
III (G31/30-37 mbar)
III (G30-G31/36 mbar
Also make sure that during the maintenance
procedure, that the operator is always able
to check whether the plug is disconnected
from the power outlet.
If work parts have to be replaced, use origi-
nal spare parts only. The manufacturer de-
clines all responsibly for injury or damage to
components due to the use of non original
parts, or extraordinary work on the applian-
ce which may modify the safety requirements
without the manufacturer's authorisation.
When ordering components, follow the in-
structions provided in the parts catalogue.
- 16 -
Distance (F) (mm)
24
+0
-1
24
+0
-1
24
+0
-1
24
+0
-1
24
+0
-1
24
+0
-1
24
+0
-1
24
+0
-1
C
B
D
ENGLISH

Publicité

Table des Matières

Dépannage

loading

Ce manuel est également adapté pour:

10tcp1ia12ncp1ia12tcp1ia20ncp2ia20tcp2ia

Table des Matières