Page. 6
N
H
d4) Replace the P.V.C protection and tighten the grommet
d5) Reclose the electrical panel.
NOTE:
Misconnecting the (N) and earth
appliance irreparably, and result in the invalidation of the
warranty!
d6) Check the tightening of the cables, thermal protections etc. as
they can loosen during transport.
d7) Replace the front panel and control panel with the provided
screws.
WARNING: the sizing of the switch and power supply
cable
needs
to
technical diagram.
1. Connection to the power supply must be made with a main switch
(H) it must be omnipolar and interrupt all contacts including neutral.
There must be a distance of at least 3 mm between open contacts,
and it must have a thermal magnetic safety switch or fuses which
are able to withstand the maximum power indicated on the plate
2.
Make sure that the power supply corresponds to that on the
technical features plate on the right side of the machine.
3.
Use an effective earthing system in compliance with local laws to
protect the safety of the operators and not damage the machine.
4. Do not use adapters, multiple sockets or extension cords.
5. The equipment must be included in an equipotential system, and
connected using a screw marked with the symbol
equipotential wire must be 10 mm²
6. When installation is completed the installer must check that the
machine is perfectly earthed
wires may damage the
be
done
consulting
2.3
ELECTRICAL CONNECTION
GB
the
attached
. The