Télécharger Imprimer la page

Bitzer CT-120-2 Traduction De La Notice D'origine page 58

Publicité

Les langues disponibles

Les langues disponibles

• Single phase failure and cable short-circuit monitoring
• Replaces SE-E1 and SE-E3.
• The previous models are fully exchangeable, with the same functionality and terminal assignment. Dimensions
and their integration into the control are also identical.
• Suitable for high power voltages between 200 .. 690 V.
• Complies with EN/UL 60730.
Technical data
Monitoring parameters
Winding temperature
Single phase failure winding temper-
ature
Cable short-circuit winding temper-
ature
Phases
Supply voltage versions
Version 1
Supply voltage
Supply voltage tolerance
Supply frequency
Version 2
Supply voltage
Supply voltage tolerance
Supply frequency
Motor supply
Motor voltage
Motor frequency
designed for soft starter
designed for FI
Relay supply
Relay voltage AC
Relay current
Relay power max.
Relay rating
Other data
Approval according to
Ambient temperature
Max. altitude
Quick acting fuse max.
Enclosure class
DIN top hat rail 35mm
CT-120-2 // PDF Download
SE-E4
Unit
x
x
x
x
110 .. 240
V
-10/+10
%
50 .. 60
Hz
24
V
-15/+10
%
50 .. 60
Hz
200 .. 690
V
50 .. 60
Hz
-
-
24 .. 240
V
0,02 .. 2,5
A
300
VA
C300
EN/UL
60730,
EN61010
-30 .. 70
°C
4000
m
4
A
IP00
x
58

Publicité

loading