Télécharger Imprimer la page

Bitzer CT-120-2 Traduction De La Notice D'origine page 55

Publicité

Les langues disponibles

Les langues disponibles

Approval according to
Ambient temperature
Max. altitude
Quick acting fuse max.
Enclosure class
DIN top hat rail 35mm
Terminal screws
Height
Width
Depth
Cable length
winding temperature monitoring
5
SE-B3
Protection functions and properties:
• Temperature monitoring
– The device locks out immediately when the preset motor winding temperature, discharge gas temperature or
oil temperature is exceeded.
• Single phase failure monitoring
• Replaces the SE-B1 and SE-B2 models with a supply voltage of 110 .. 240 V.
The SE-B2 remains available as an evaluation unit for oil flow monitoring.
• The previous models are fully exchangeable, with the same functionality and terminal assignment. Dimensions
and their integration into the control are also identical.
• Does not comply with EN/UL 60730 ➨ SE-B5 .
Technical data
Monitoring parameters
Winding temperature
Single phase failure winding temper-
ature
Supply voltage versions
Version 1
Supply voltage
Supply voltage tolerance
Supply frequency
Relay supply
Relay voltage AC
Relay voltage DC
Relay current
CT-120-2 // PDF Download
SE-B2
Unit
UL508,
EN61010
-30 .. 70
°C
3000
m
4
A
IP00
x
x
50
mm
68,3
mm
32,5
mm
350
mm
SE-B3
Unit
x
x
110 .. 240
V
-10/+10
%
50 .. 60
Hz
24 .. 240
V
min. 24
V
0,02 .. 2,5
A
55