DPRO500
ENGLISH
Instructions translated from Italian
Contents
IMAGES (beginning of the manual) ............................................................................... I-III
GENERAL WARNINGS: SAFETY - INSTALLATION - USE ...............................................1
1 - PRODUCT DESCRIPTION AND INTENDED USE .......................................................3
2 - INSTALLATION...........................................................................................................3
2.1 - Tests prior to installation................................................................................................................. 3
2.2 - Product application limits ............................................................................................................... 3
2.3 - Installation of the control unit ......................................................................................................... 3
3 - ELECTRICAL CONNECTIONS ...................................................................................5
3.1 - Connecting the three-phase power supply cable .......................................................................... 5
3.2 - Connecting the single-phase power supply cable .......................................................................... 5
3.3 - Changing the power supply through the jumper ............................................................................ 5
3.4 - Description of the electrical connections: power supply, safety and control devices,
and accessories ............................................................................................................................ 5
3.5 - Electrical connections of the control unit ....................................................................................... 5
3.6 - STOP SAFETY EDGE Input .......................................................................................................... 5
3.7 - Connecting a radio receiver ........................................................................................................... 6
3.8 - Initial startup and electrical connections test .................................................................................. 6
3.9 - Total deletion of the control unit memory ....................................................................................... 6
3.10 - Recognition of the connected devices and the Opening and Closing positions ............................ 6
3.10.1 - Recognition of the Opening and Closing positions with mechanical limit switch ........................ 6
3.11 - Operating modes ......................................................................................................................... 7
3.12 - Oview programming unit ............................................................................................................. 7
4 - TESTING AND COMMISSIONING ..............................................................................7
4.1 - Testing ........................................................................................................................................... 7
5 - INSTALLATION AND ELECTRICAL CONNECTION OF TWO CONTROL UNITS
FOR LEAVES MOVING IN OPPOSITE DIRECTIONS ..................................................7
6 - FURTHER DETAILS AND DIAGNOSTICS ...................................................................7
6.1 - Further details ............................................................................................................................... 7
6.1.1 - Signals when switching ON ........................................................................................................ 7
6.1.2 - Other functions ........................................................................................................................... 7
6.2 - Diagnostics ................................................................................................................................... 8
7 - BASIC TROUBLESHOOTING.....................................................................................9
8 - PRODUCT DISPOSAL ...............................................................................................9
9 - TECHNICAL SPECIFICATIONS ................................................................................ 10
CE DECLARATION OF CONFORMITY...........................................................................11
Before performing any type of operation or
procedure, read carefully the general instructions
(page 1) and the application limits (paragraph 2.2)
IMPORTANT!
1
PRODUCT DESCRIPTION AND INTENDED USE
The DPRO500 control unit is designed to control electromechanical actuators
for automating gates, sectional doors or shutters.
CAUTION! – All uses other than the intended use described and use
in environmental conditions other than those described in this manual
should be considered improper and forbidden!
The control unit can be connected to all common safety elements. To open and
close a gate, you only need to operate the appropriate button installed on the
cover or the external button or via a radio receiver.
2
INSTALLATION
2.1 - Pre-installation checks
Before proceeding with installation, check the condition of the product com-
ponents, suitability of the selected model and conditions of the intended instal-
lation environment:
• Check that all the materials are in good working order and suited to the
intended use.
• Check that all conditions of use fall within the "application limits" of the
product (paragraph 2.2) and the value limits shown in the "Product technical
characteristics".
• Check that the installation location is compatible with the overall dimensions
of the product.
• Check that the surface chosen for installing the product is solid and can
ensure stable attachment.
• Make sure that the installation area is not subject to flooding; if necessary, the
product may be installed, appropriately raised above ground level.
• Check that the space around the product allows safe and easy access.
• Check that all electrical cables to be used belong to the type listed in Table 1.
• Check that the automation has mechanical stops in both the opening and
closing phases.
2.2 - Product application limits
The product is only to be used as indicated in the following table:
Control unit power supply
Type of motor*
Three-phase 3x400 Vac -
Three-phase 3x400 V AC – 50/60 Hz – with
50/60Hz
Nice encoder or mechanical limit switches
Single-phase 1x230 Vac -
Single-phase 1x230 V AC – 50/60 Hz – with
50/60Hz
Nice encoder or mechanical limit switches
(*) In respect of the corresponding application limits.
For single-phase motors, see Paragraph 3.2.
CAUTION! – The control unit described in this instruction manual
cannot be used in areas subject to the risk of explosion.
Important – Before installation, prepare the electrical cables required for the
system, by referring to "Table 1 - Technical specifications of electrical cables"
Caution! – When laying the ducting for routing the electrical cables and for
the cable entry point into the control unit housing, be aware that due to pos-
sible deposits of water in the junction wells, the connection ducts might create
condensate in the control unit, with consequent damage to the electronic cir-
cuits.
2.3 - Installation of the control unit
Proceed as follows when installing the control unit:
01. Open the control unit box: unscrew the screws as shown in Fig. 1-A /
Fig. 1-B;
02. Prepare the holes for routing the electrical cables for the accessories pro-
viding control and/or signalling functions. For this purpose, we recommend
using a special tool (e.g. hole cutter) on the marked positions at the bottom
of the box, also to ensure maintaining the level of IP protection. If neces-
sary, you can use the lateral cable entry points, but only by using suitable
ducting connections;
03. Secure the box. You can secure it in three ways:
a) directly onto the wall using the screws from inside the box (Fig. 2-A);
b) using the standard supports supplied (Fig. 2-B);
c) if the cable duct for routing the electrical cables is on the outside and
you need to fix the box at a maximum distance of 2 cm away from the wall
to allow the cables to be routed behind the control unit. NDA100 consists
of 4 spacers and a protective cover for introducing the cables inside the
control unit box. To install the unit using the (optional) accessory, refer to
Fig. 2-C.
04. At this point, you can make all the electrical connections: see Chapter 3.
To install the other devices used on the automated system, refer to the respec-
tive instruction manuals.
.
English – 3