Parameterization
Key
ON key
OFF key
O
Jog key
Jog
Reversing key
Toggle key
P
Reset key
Reset
Raise key
Lower key
Sign key
+/-
Number keys
to
NOTE
8-10
Significance
For energizing the drive (enabling motor activation). The
function must be enabled by P554.
For de-energizing the drive by means of OFF1, OFF2 or
OFF3, depending on parameterization. The function
must be enabled by P554 to P560.
For jogging with jogging setpoint 1 (only effective when
the unit is in the "ready to start" state). This function must
be enabled by P568.
For reversing the direction of rotation of the drive. This
function must be enabled by P571 and P572.
For selecting menu levels and switching between
parameter number, parameter index and parameter
value in the sequence indicated. The current level is
displayed by the position of the cursor on the LCD
display (the command comes into effect when the key is
released).
For conducting a numerical input
For leaving menu levels
If fault display is active, this is for acknowledging the
fault. This function must be enabled by P565.
For increasing the displayed value:
Short press = single-step increase
Long press = rapid increase
If motorized potentiometer is active, this is for raising the
setpoint. This function must be enabled by P573.
For lowering the displayed value:
Short press = single-step decrease
Long press = rapid decrease
If motorized potentiometer is active, this is for lowering
the setpoint. This function must be enabled by P574.
For changing the sign so that negative values can be
entered
Numerical input
Table 8-3
Operator control elements of the OP1S
If you change the value of a parameter, the change does not become
effective until the toggle key (P) is pressed.
Parameter changes made using the OP1S are always stored safely in
the EEPROM (protected in case of power failure) once the toggle key
(P) has been pressed.